AVR400 System User Guide
Figure 9. AVR400 Dimensions
4.3 Electrical Specifications The following table provides the electrical specifications for the AVR400 system. Feature Specification Voltage requirement 120/240 VAC Power requirement 1200W peak, 200W typical Power Supplies External AC power adapter, 100/240 VAC, for metrology unit and PC 4.3.1 Electrical Power The AVR400 system is powered by an external power adapter. The following table provides the specifications of the AC adapter. Feature Specification Output 48 VDC output Voltage requirement 100/240 VAC power for worldwide us Maximum combined current draw 10.0A at 120 VAC 5.00A at 240 VAC The power adapter is normally placed on the floor. Before doing so, verify that the floor will never be flooded or hosed down for cleaning. If there is danger of contact with water on the floor, place the adapters in a higher, protected location.
24 of 62
Uncontrolled When Printed
9985 Revision A
Made with FlippingBook - professional solution for displaying marketing and sales documents online