INDEX
Drawer Systems SERVO-DRIVE flex For Refrigerator and Freezer Applications
Drawer Systems SERVO-DRIVE flex
Planning Information for Refrigerator and Freezer Applications
1
Drive unit
1x
7
Chipboard screw
11x
9
Connecting node
1x
Preparation/drilling
Drive unit opens handle-less refrigerators, freezers and dishwashers. 2x Mounting plate for clipping on the drive unit and the front. 2x Fitting for fastening the front to the side mounting plates. Mounting plate Front fastening
This node establishes the electrical connection between the distribution cable and the transformer.
8
Assembly template 1x For positioning the mounting plate on the side of the cabinet.
2
3
8
4
Front cover
1x
Cover guarantees a consistent appearance.
2
min 10
8
5
*A 1mm gap on all sides is required for the inset front.
5
Catch plate 1x Catch plate for assembly on the front. This guarantees secure closing when opened unintentionally. 3x The Blum distance bumper ensures the required trigger path of 2mm. Blum distance bumper
6
1
3
Drilling for mounting plate
Drilling front for bumper
Drilling front
7
9
INSTALLATION OPTIONS:
6
4
Access gap – measurements
APPLICATION: Refrigerator up to NH 1780 mm, freezer up to NH 1580 mm
Freezer ≥ NH 1780 mm
Fridge/freezer combination
Installation situations (number of SERVO-DRIVE flex units required depends on the respective application)
2 x SERVO-DRIVE flex set
2 x SERVO-DRIVE flex set
1 x SERVO-DRIVE flex set
ORDER SPECIFICATION: SERVO-DRIVE flex set
Connecting node (1x) & Cable end protector (2x) Blum No
Components included: 1 x drive unit, 2 x mounting plate, 2 x front fastening, 1 x front cover, 1 x catch plate, 3 x Blum distance bumper, 11 x chipboard screw, 1 x assembly template, 1 x connecting node *Number of SERVO-DRIVE flex sets required depends on the application Blum No Code Z10C500A 1-244-090 SERVO-DRIVE transformer* Blum No Code Z10NE020D 1-244-050 Cable & plug Blum No Code Z10M200K 1-244-051 Transformer base housing 1x Blum No Code Z10NG000 1-244-053 Alternative: Transformer panel housing 1x Blum No Code Z10NG120 1-244-055
Code
Z10V100E.01
1-244-079
SERVO-DRIVE cable**
Blum No
Code
8m for cutting to size.
Z10K800AE
1-244-080
Cable holder
Blum No
Code
1-244-007
Z10K0009
Note: For applications with two SERVO-DRIVE flex units on additional synchronisation cable, connecting node, cable end protector and cable holder are required.
*SERVO-DRIVE flex is an application for SERVO-DRIVE. A transformer is required for power supply. **The SERVO-DRIVE cable is used for attaching the SERVO-DRIVE flex unit to the power supply and for synchronising applications connecting two SERVO-DRIVE flex units.
General notes
If the door of the device is left open for a relatively long time, for example when putting away shopping, a vacuum may be created inside the refrigerator or freezer after it has been closed. This may result in it not being possible to open the door of the device for a few seconds. This vacuum normally disappears after a short amount of time and the opening function becomes fully operational once again.
CONTENTS
B.194
B.195
DRAWER SYSTEMS
DRAWER SYSTEMS
Dimension data and specifications may change without notification.
LINCOLN SENTRY