Lift & Flap Systems AVENTOS HF, HS, HL & HK

Lift & Flap Systems AVENTOS HF, HS, HL & HK

ASSEMBLY, REMOVAL & ADJUSTMENT - SERVO-DRIVE

ASSEMBLY, REMOVAL & ADJUSTMENT - SERVO-DRIVE

Start-up

SERVO-DRIVE switch

Drive unit – AVENTOS HF, HS, HL

Please see the installation instructions or go to www.blum.com for more details about start-up

Setting up the wireless connection between the SERVO-DRIVE switch and the drive unit. A SERVO-DRIVE switch can only be assigned to one unit. All switches must be activated from the reference run

$MJDL

Activation

Removal

Drive unit

Code

SERVO-DRIVE switch

AVENTOS HF, HS, HL

1-320-101

Drive unit – AVENTOS HF, HS, HL

Press the button until the LED flashes

Press the SERVO-DRIVE switch until the LED lights up continuously

Removal

Reference run

Drive unit

Code

The drive unit recognises the required parameters using the reference run

Note: The settings for the lift mechanism, gaps or lever as well as the assembly of the opening angle stop must take place before the reference run. If required reset the reference run = “Reset Motion”

AVENTOS HF, HS, HL

1-320-101

Drive unit – AVENTOS HK

Operation

Min. 10 s

Reference run

Removal

Drive unit

Code

AVENTOS HK

1-321-015

Blum transformer 72 W

Reference run is required: LED flashes

Close the front manually

Press on front: the reference run starts automatically

Front opens and closes 2 times automatically – the process should not be interrupted or stopped

Removal

Blum No Code Z10NE050.0* 1-244-050 Z10V100E.01 1-244-079