Electrical Units & Accessories
Technical information Informations techniques
OK
NO
15 cm 15 cm
25 cm
10 l 15 min
BUILT-IN FLOOR LUMINAIRES - DRAINAGE It is essential to follow the assembling instructions and the instal- lation guide of the built-in luminaires in order to achieve the best performance. 1. Avoid installing the luminaires in terrain depressions. 2. Avoid installing the luminaires in areas where water can accumu- late and in places that are permanently damp, such as gardens or lawns. 3. Avoid the use of chemical products used to fertilise gardens be- cause they could damage some of the components. 4. Level the luminaire with the surface. 5. Anticipate a dilation coating for built-in luminaires installed on surfaces like cement or concrete, to avoid possible dilation or compression. 6. Install an effective drainage system to avoid the accumulation of water, at least 25 cm of gravel under the installation casing. A cor- rect drainage must absorb up to 10 litres of water in 15 minutes. 7. Put the light on for 20 minutes without the glass to avoid conden- sation inside.
ENCASTRABLES AU SOL – DRAINAGE Il est indispensable de suivre les instructions et le guide d’installation des encastrables afin de garantir un éclairage optimum. 1. Eviter l’installation de luminaires dans des zones de dépression de terrain. 2. Eviter l’installation de luminaires dans des espaces où s’ accumule de l’eau ou des zones humides telles que jardins ou pelouses. 3. Eviter l’utilisation de produits chimiques utilisés pour le composta- ge des jardins car ils peuvent détériorer certains composants. 4. Niveler le terrain en vue de l’installation des luminaires. 5. Prévoir un recouvrement pour la dilatation dans le cas de luminai- res encastrables installés en surface tel que le ciment ou le béton, afin d’éviter une possible dilatation ou compression. 6. Poser un drain efficace afin d’éviter toute stagnation de l’eau, avec un minimum de 25 centimètres de gravier en dessous de l’installa- tion. Un drain efficace doit permettre d’absorber jusqu’à 10 litres d’eau en 15 minutes. 7. Faire fonctionner le luminaire pendant 20 minutes, sans le verre, afin d’ éviter toute condensation d’eau à l’intérieur.
Installation recommendations Conseils d’installation
Products with a remote driver. Install the driver within 2 metres of the product when the EMC levels for each application cannot be checked, in accordance with reference standards. The polarity of the product’s cables must be checked before they are connected to the driver’s secondary side, given that the incorrect polarity may damage the LED module and/or driver. Control. Control signal cables must be installed separately from power cables. Switches are not permitted on the driver’s secondary side. Phase-cut control. -Basic phase-cut control. Does not require additional cables. -Products with an L-control driver: they enable control with TRIAC/IGBT dimmers; leading-edge/forward-pha- se control. -Products with a C-control driver: they enable control with IGBT dimmers; trailing-edge/reverse-phase control. -Products with LC-control driver: they allow both aforementioned types of dimmers. -Check dimmer-driver compatibility. Push control. Requires an additional cable. NO (Normally Open) push buttons should be used. A quick press switches the product on or off. If the button is pressed and held, the brightness level is adjusted. 0/1-10V control. Analogue control that requires two additional polarised cables. A dimmer generates a constant voltage signal between 0 and 10V. If a voltage of 1V is applied, the driver will adjust the product’s brightness to the minimum, however, when a voltage of 10V is applied, the product’s brightness will be set to its maximum. The drivers that allow a control signal between 0-10V are capa- ble of switching off the product completely when they receive a signal of 0V from the dimmer. DALI/DALI-2 control. Digital control protocol developed by leading driver manufacturers to create a control standard in the lighting industry. It allows scenes to be memorised, messages to be sent in the event of a breakdown or the end of the product’s life, point-to-point product control and planning, and emergency manage- ment. It requires two additional non-polarised cables. A cable with a cross-section of 1.5mm2 is recommended. DALI-2 certification improves interoperability between DALI devices. DMX control. Digital control protocol used in the world of show lighting. It requires two additional pola- rised cables. Using a twisted, shielded cable with an impedance of 120Ω is recommended. Casambi control. Bluetooth Mesh control system We recommend not to exceed 15m distance between devices, nor to use metal enclosures that may affect wireless communication. Produits à driver distant. Il est recommandé d’installer le driver à un maximum de 2 mètres du produit lorsqu’il n’est pas possible de vérifier les niveaux de compatibilité électromagnétique (CEM) de chaque application, conformément aux normes de référence. Il est nécessaire de vérifier la polarité des câbles du produit avant de les relier au secondaire du driver, car une mauvaise connexion risque d’endommager le module LED et/ou le driver. Variation. Les câbles de signal de variation doivent être installés séparément des câbles d’alimentation. Il n’est pas permis d’installer des interrupteurs sur le secondaire du driver. Réglage par ligne (coupure de phase). -Réglage de base par ligne : n’exige pas de câbles supplémentaires. -Produits munis d’un driver de variation de type « L » : admettent le réglage avec des dimmers de type TRIAC/ IGBT ; réglage par début de phase (leading edge/forward phase control). -Produits munis d’un driver de variation de type « C » : admettent le réglage avec des dimmers de type IGBT ; réglage par fin de phase (trailing edge/reverse phase control). -Produits munis d’un driver de type « LC » : admettent les deux types de dimmers susmentionnés. -Il est conseillé de vérifier la compatibilité dimmer-driver. Réglage Push. Exige un câble supplémentaire. Il convient d’utiliser des boutons poussoirs NO (normalement ouverts). Il suffit d’appuyer rapidement dessus pour allumer ou éteindre le produit. Maintenir le bouton poussoir enfoncé permet de régler le niveau de luminosité. Réglage 0/1-10 V. Réglage ana- logique qui exige deux câbles supplémentaires à polarité. Un dimmer génère un signal à tension constante de 0 à 10 V. Appliquer une tension de 1 V permet de régler la luminosité du produit au minimum, tandis qu’en appliquant une tension de 10 V, le produit brillera au maximum. Les drivers prenant en charge un signal de réglage doté d’une plage comprise entre 0 et 10 V sont capables d’éteindre complètement le produit lorsqu’ils reçoivent 0 V du dimmer. Contrôle DALI/DALI-2. Protocole de contrôle numérique mis au point par les principaux fabricants de drivers pour créer une norme de réglage dans le secteur de l’éclairage. Il permet la mémorisation de scènes, l’envoi de messages en cas de panne ou en fin de vie du produit, le contrôle et la planification point par point du produit, ainsi que la gestion des situations d’urgence. Exige deux câbles supplémentaires sans polarité. Il est conseillé d’utiliser un câble de section de 1,5 mm2. La certification DALI-2 améliore l’intero- pérabilité entre dispositifs DALI. Contrôle DMX. Protocole de contrôle numérique utilisé dans le domaine de l’éclairage de spectacles. Exige deux câbles supplémentaires avec polarité. Il est conseillé d’utiliser un câble torsadé, blindé et doté d’une impédance de 120 Ω. Contrôle Casambi. Système de contrôle Bluetooth Mesh. Il est recommandé de ne pas dépasser une distance de 15 m entre les dispositifs, ni d’utiliser de boîtiers métalliques qui affectent la communication sans fil.
Made with FlippingBook interactive PDF creator