Settings – Maintenance Access Level
1.
2.
1. Temporary Purge Time – Allows operator to temporarily reduce the purge time for troubleshooting purposes. It is not recommended to reduce the purge time if there is product in the oven. 2. Flow Delay – Allows the operator to adjust the amount of time an air pressure switch must be open before the burner is shut down and a fault is issued. Adjust the setting to a higher value if the oven is experiencing random shutdowns with automatic re-purge (no alarm buzzer).