PAAS SB V4.3

Industrial Grey PVC-U Pipe And Fittings Electric Actuated PP-H Valves

PP-H Electric Actuator Overview

Electric Actuator Range EA15/EA25/ EA45 / EA120 / EA250

 Coloured LED indicator of open/close

 Easy set up, push button setting of open/closed position feedback

Actuator Options

EA15

EA25

EA45

EA120

EA250

240 Volt Code

198 153 180

198 153 182

198 153 184

198 153 186

198 153 188

24 Volt Code

198 153 181

198 153 183

198 153 185

198 153 187

198 153 189

Nominal Power 240 V AC

30 VA

35 VA

55 VA

50 VA

60 VA

24 V

35 VA

40 VA

60 VA

55 VA

65 VA

Current 240V AC

0.13A

0.15A

0.24A

0.22A

0.26A

Current 24V DC

1.5A

1.7A

2.5A

2.3A

2.7A

Torque - Nominal

10 Nm

10 Nm

20 Nm

60 Nm

100 Nm

Torque - Peak

20 Nm

25 Nm

45 Nm

120 Nm

250 Nm

Duty Cycle

< 40%

100%

50%

50%

35%

Cycle time s/90 ° at Mdn

5 s

5 s

6 s

15 s

20 s

Flange Fitting

F05

F05

F05

F07

F07

Tested cycles(at 20 °C and Mdn

150 000

250 000

100 000

100 000

75 000

Weight

1.85 kg

2.1 kg

2.2 kg

3.6 kg

5.0 kg

Position Feedback

Yes

Yes

Yes

Yes

Yes

Accessories

No

Yes

Yes

Yes

Yes

Ball Valve Sizing

DN10-DN50

DN10-DN50

DN65

DN80-100

-

Butterfly Valve Sizing

-

-

DN50-65

DN80-DN200

DN250-DN300

Housing

PP-GF - for very good chemical resistance

Actuator Accessories for EA Type 15

Unit

Suits

Code

Fail-safe return unit (integrated) Fail-safe return unit (external)

Moves actuator in pre-defined safe position upon power loss, integrated battery pack

199 190 610 199 190 611

Moves actuator in pre-defined safe position upon power loss, voltage supply implemented externally

Actuator Accessories for EA Type 25/45/120/250

Unit

Suits

Code

Fail-safe return unit (integrated) Fail-safe return unit (external)

Moves actuator in pre-defined safe position upon power loss, integrated battery pack

199 190 601 199 190 604 199 190 603 199 190 602

Moves actuator in pre-defined safe position upon power loss, voltage supply implemented externally

Positioner Monitoring

Continuous actuator control. 4-20mA or 0-10 V input and 4-20 mA Feedback

Parameter monitoring. Generates alarm upon reaching its set limitations. Prevents water hammers or indicates maintenance need for valve.

Profibus DP

Enables the actuator to be connected to a Profibus DP-V0 network Enables to read from the actuator main board and check configurations

199 190 605 199 190 600

Diagnostic Tool

120 PAAS Source Book

www.paas.com.au

V 4.3