i. Human Habitation Prohibited . Accessory structures shall not be used for human habitation, (including working, sleeping, living, cooking or restroom areas).
ii. Temperature Control Prohibited . Accessory structures shall not be temperature controlled.
iii. Flood Damage Potential . Accessory structures shall be designed to have low flood damage potential.
iv. Placement & Construction . Accessory structures shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters. v. Anchoring . Accessory structures shall be firmly anchored in accordance with §9-1401 Flood Damage Prevention Regulations, k. Provisions for Flood Hazard Reduction, (1) General Standards, A. Anchoring. vi. Services . All service facilities such as electrical shall be installed in accordance with §9-1401 Flood Damage Prevention Regulations, k. Provisions for Flood Hazard Reduction, (1) General Standards, D. Construction Standards. vii. Flood Openings Required . Flood openings to facilitate automatic equalization of hydrostatic flood forces shall be provided below regulatory flood protection elevation in conformance with §9-1401 Flood Damage Prevention Regulations, k. Provisions for Flood Hazard Reduction, (2) Specific Standards, D. Elevated Buildings, iii, Flood Openings. viii. Accessory Structure Under 150 Square Feet . An accessory structure with a footprint less than 150 square feet that satisfies the criteria outlined above does not require an elevation or flood proofing certificate. Elevation or flood proofing certifications are required for all other accessory structures in accordance with §9-1401 Flood Damage Prevention Regulations, h. Floodplain Development Application; Permit Procedures & Certification Requirements, (3) Certification Requirements.
I. Tanks . When gas and liquid storage tanks are to be placed within a Special Flood Hazard Area or Future Conditions Flood Hazard Area, the following criteria shall be met:
Made with FlippingBook interactive PDF creator