Hot Runner & Control Systems

Smart Series ®

130 140

page content text

RoHS/WEEE Compliant: Mold Power Input Connectors

For 15 AMP Applications

Mold Power Input Connectors are mounted on the mold to accept power cable(s) from the Mainframe. They are supplied with six inches of numbered leads and a ground wire. All three 15 AMP connectors are the same physical size and use 14-gauge wire. Only the number of active pins change. The 30 AMP connectors are supplied with 10-gauge leads and are attached to screw terminals. Each is equipped with an integral retaining latch to provide a secure cable connection. Connector configuration ensures proper insertion of cable. Splicing of 6" leads to heater power leads is easily accomplished with the Insulated Crimp Connectors supplied.

PIC5G

NOTE:  Ground wire must be connected to mold to ensure operator safety.

PIC8G

Mold Power Input Connectors

PIC12G

NOTE: Replacement parts and extraction tools can be found on page 146

For 30 AMP Applications

NOTE: Dimensions shown may vary slightly.

PICH23G

Insulated Crimp Connectors

PICH5G

NOTE:  Initial supply is provided with mold power input connectors. Also, see page 126.

NOTES: Connector PICH23G is dimensionally identical to thermocouple connector MTC8G. See next page. For PICH23G and PICH5G, direct wiring without crimp connectors is possible by removing 6" leads .

U.S. 800-626-6653  Canada 800-387-6600  dme.net  store.dme.net

Made with FlippingBook - professional solution for displaying marketing and sales documents online