page content text Smart Series ®
150
Temperature Alarm/System Control Modules
TAS0512/11 Temperature Alarm Function • Provides alarm for over or under temperature, or diagnostic error • Provides visual and audible indications of an alarm • The audible alarm (2) can be turned on or off with switch (4) • Relay contacts (5) are provided to allow hook-up of remote equipment such as a light, a conveyor or a machine function • Relay contacts are unaffected by the position switch (4) • An infinite number of zones of control can be monitored as long as they are contained within the same communications-style mainframe as the TAS module
1
2
System Control Functions Up to 63 zones can be controlled remotely at one time. These zones must be contained within the same communications-style mainframe as the TAS module.
3
4
5
NORMAL / IDLE • Rotary switch (6) provides remote control of DSS1502/01, DSS1512/11, CSS1502/01, SSM1502/01, and SSM1512/11 • Control modules can all be commanded to respond from NORMAL to IDLE (Standby Heat) • In IDLE, the modules will adjust to a setting of 93˚C (200°F) Exceptions: SSM1502/01 and SSM1512/11 adjust to a setting of 100˚C (212°F) • Moving the rotary switch back to NORMAL restores all modules to their established setpoints • The user can select IDLE for temporary lowering of all zones to prevent material degradation • This feature can be used to keep heaters warm enough to prevent absorption of moisture BOOST / OFF • The SSM1502/01 and SSM1512/11 can be placed into BOOST and OFF • BOOST will raise the setpoint of the module by 10, 20, or 30% • OFF shuts off power to the heater but allows the user to monitor cool down of the hot runner system • Each SSM1502/01 and SSM1512/11 can be individually programmed to respond to OFF, IDLE and BOOST commands • The user can quickly drive all nozzle zones into BOOST to open frozen gates
6
7
Front Panel Controls and Indicators 1. Power On Indicator: LED illuminates when power is applied to the module. 2. Audible Alarm: Emits a loud audible alarm when the alarm switch (4) is placed in the “1” position (ON) and an alarm condition is sent by a compatible control module. 3. Alarm Indicator: LED illuminates when an alarm condition is sent by a compatible module. 4. Audio Alarm On/Off Switch: Turns the audio alarm (2) on or off. 5. Alarm Relay Connector Provides relay contacts for use with remote equipment. Mating connector is supplied. 6. System Control Switch: Activates the OFF, IDLE and BOOST mode in all compatible modules. 7. Power On/Off Switch: C ontrols AC power to the module.
U.S. 800-626-6653 Canada 800-387-6600 dme.net store.dme.net
Made with FlippingBook - professional solution for displaying marketing and sales documents online