text
33
23
Gate Details for use with Hardened Steel (50HRC min.) Stellar Systems
Fig. 6
Gate Details for Standard Point Gate, High Performance Point Gate Tips (SXG5110 & SXG5020) For gating onto a flat surface or into a recess* (“dimple”)
Ø2mm/0.08in x 45°
Ø19.0mm/ 0.75in CLEARANCE DIAMETER
5mm/.20in MIN DISTANCE BETWEEN WATERLINE AND DROP
R 0.25mm/ 0.010in MIN R 3.00mm/ 0.118in MAX
+0.005 –0.000
+.0002 –.0000
Z DIMENSION
Ø9.800mm
/.3858in
+0.13
+.005 –.000
2.03mm
/.080in
–0.00
30°
90°
R0.25mm/.010in MIN R0.38mm/.015in MAX
5mm/ .20in MIN
+.000 –.005
+0.00
2.54mm
/.100in
–0.13
0.13mm/.005in MAX LAND
0.89mm/.035in MAX*
R4.76mm/.187in
R3.18mm/.125in*
0.62mm/.024in To Bottom of Radius
R12.70mm/.500in MIN*
MIN GATE DIAMETER Ø0.71mm/.028in for unlled resins Ø1.27mm/.050in for lled resins
NOTES for Figure 6 & 7: 1. If gate detail does not properly fit the application, contact DME for assistance about gate detail options. 2. Position gate detail within ±0.013mm/.0005in from nominal. 3. T he gate diameter can be opened by the customer to suit the application. (The land must be re-machined to the maximum dimension after increasing the gate diameter.) 4. Water lines are required in “A” plate for proper gate cooling. 5. P osition water lines as close as possible but not closer than the minimum distance shown to provide a safe steel condition. 6. F or faster color changes, remove (“decone”) the resin from the front of each point gate tip prior to changing colors. 7. T he minimum “Z” dimension is 13.00 and the maximum “Z” dimension is 115 for point gate and sprue gate tips.
Fig. 7
Gate Details for Sprue Gate Tips, SXT7040 & SXT7140
19.5 0.77 SXT7140 19.0 0.75 SXT7040
5 0.20 MIN
45°
30°
5 0.20 MIN
+ 0.005 0.000 0.3937
+0.0002 0.0000
10.000
SXT7040
3.30 0.130 MAX RUNNER HEIGHT
+ 0.012 0.000 0.7500
+0.0005 0.0000
19.050
SXT7140
U.S. 800-626-6653 n Canada 800-387-6600 n dme.net n store.dme.net