text
33
23
Gate Details for use with Hardened Steel (50HRC min.) Stellar Systems
Fig. 6
Gate Details for Standard Point Gate, High Performance Point Gate Tips (SXG5110 & SXG5020) For gating onto a flat surface or into a recess* (“dimple”)
Ø2mm/0.08in x 45°
Ø19.0mm/ 0.75in CLEARANCE DIAMETER
5mm/.20in MIN DISTANCE BETWEEN WATERLINE AND DROP
R 0.25mm/ 0.010in MIN R 3.00mm/ 0.118in MAX
+0.005 –0.000
+.0002 –.0000
Z DIMENSION
Ø9.800mm
/.3858in
+0.13
+.005 –.000
2.03mm
/.080in
–0.00
30°
90°
R0.25mm/.010in MIN R0.38mm/.015in MAX
5mm/ .20in MIN
+.000 –.005
+0.00
2.54mm
/.100in
–0.13
0.13mm/.005in MAX LAND
0.89mm/.035in MAX*
R4.76mm/.187in
R3.18mm/.125in*
0.62mm/.024in To Bottom of Radius
R12.70mm/.500in MIN*
MIN GATE DIAMETER Ø0.71mm/.028in for unlled resins Ø1.27mm/.050in for lled resins
NOTES for Figure 6 & 7: 1. If gate detail does not properly fit the application, contact DME for assistance about gate detail options. 2. Position gate detail within ±0.013mm/.0005in from nominal. 3. The gate diameter can be opened by the customer to suit the application. (The land must be re-machined to the maximum dimension after increasing the gate diameter.) 4. Water lines are required in “A” plate for proper gate cooling. 5. Position water lines as close as possible but not closer than the minimum distance shown to provide a safe steel condition. 6. For faster color changes, remove (“decone”) the resin from the front of each point gate tip prior to changing colors. 7. The minimum “Z” dimension is 13.00 and the maximum “Z” dimension is 115 for point gate and sprue gate tips.
Fig. 7
Gate Details for Sprue Gate Tips, SXT7040 & SXT7140
19.5 0.77 SXT7140 19.0 0.75 SXT7040
5 0.20 MIN
45°
30°
5 0.20 MIN
+ 0.005 0.000 0.3937
+0.0002 0.0000
10.000
SXT7040
3.30 0.130 MAX RUNNER HEIGHT
+ 0.012 0.000 0.7500
+0.0005 0.0000
19.050
SXT7140
U.S. 800-626-6653 n Canada 800-387-6600 n dme.net n store.dme.net
Made with FlippingBook - professional solution for displaying marketing and sales documents online