EcoONE-Series Thermal Expansion Allowance Hot Sprue Bushings
68
THERMAL EXPANSION ALLOWANCE The expansion factor must be taken into consideration prior to machining and installing the nozzle. This factor must be added to the nozzle nominal “A” dimension. Z-1 = Nozzle Length “A” + “BE” Thermal Expansion (ΔL) - Nozzle Plate Thickness The formula for determining the thermal expansion is as follows: BE = “A” dimension * 0.0000115 * (nozzle setpoint temperature - mold temperature °C) Note: The expansion coefficient for °F is 0.00000633 EXAMPLE: Nozzle “A” dimension 120mm, setpoint temperature 260°C, mold operating temperature 50°C. BE = 120mm * 0.0000115 * (260° - 50°) = 0.2898mm. Thus nozzle length “A” 120mm + BE 0.2898 = 120.290mm
Tip Assembly T/C Heater Sleeve
T/C Retaining Clips
Heater Wires Power & T/C
Locating Ring
EcoONE SNHR / HSB Nozzle Pocket Dimensions
NOZZLE SERIES
Ø01
Ø02
H1 2.6 2.6 2.6 2.6 4.6 4.6
H2 4.5 4.6 4.7 4.7 6.7 7.1
H5 4.5
H6
EcoONE-04 EcoONE-06 EcoONE-08 EcoONE-10 EcoONE-12 EcoONE-16
8
18 28 30 34 36 42
14.5
10 12 14 16 20
5 5 5
15 15 15 14 17
6.5
7
THERMAL SPRUE THERMAL FULL BODY
THERMAL EXT SPRUE THERMAL EXT FULL BODY
THERMAL BODILESS
Ø02
Ø02
Ø02
H1
H2
H6
H5
Ø01
Ø01
Ø01
ØG
ØG
ØG
EcoONE SNHR / HSB Plate & Nozzle Pocket Dimensions
HEAD HEIGHT mm
B DEPTH mm (+0.02mm / -0.00mm)
C DEPTH mm
D DIA mm
E DIA mm (+0.02mm /-0.00mm)
F DIA mm
PS mm MINIMUM
CT/AP mm MINIMUM
NOZZLE SERIES
EcoONE-04 EcoONE-06 EcoONE-08 EcoONE-10 EcoONE-12 EcoONE-16
15 20 20 20 20 20
15 20 20 20 20 20
12.5 16.5 16.5 16.5 16.5 16.5
31 42 46 48 48 54
25 36 40 42 42 48
18 28 30 32 36 42
15 15 15 15 15 15
33 38 38 38 38 38
+0.05 -0.00
101.40
F DIA E DIA D DIA 77.00
IF WATER LINES ARE REQUIRED IN THE CAVITY PLATE ROUTE THEM AWAY FROM THE NOZZLE HEAD
INSULATOR 6.35
100.00
8.00 MIN
(NOZZLE "L") L = Z-1 - PS + L
WATER LINES ARE RECOMMENDED IN THE "A" PLATE
U.S. 800-626-6653 n Canada 800-387-6600 n DME.net n store.DME.net