Integrally Heated Hot Sprue Bushings Integrally Heated Sprue Bushings .750" SERIES SPECIFICATIONS
89
Integrally Heated Sprue Bushing - 750 Series
Gate Style
L Dim.
L2 Dim.
.500 Radius Head Watts
Thermocouple
Sprue
2.375"
(60.3)
1.500"
(38.1)
SB031000
315
MT020020
2.875"
(73.0)
2.000"
(50.8)
SB031008
370
MT020020
3.375"
(85.7)
2.500"
(63.5)
SB031016
425
MT020020
4.375"
(111.1)
3.500"
(88.9)
SB031032
535
MT020021
Gate Style
L Dim.
L2 Dim.
.500 Radius Head .750 Radius Head Watts
Thermocouple
Extra Stock Sprue
2.875"
(73.0)
2.000"
(50.8)
SB031004
315
MT020020
3.375"
(85.7)
2.500"
(63.5)
SB031012
370
MT020020
3.875"
(98.4)
3.000"
(76.2)
SB031020
425
MT020020
4.375"
(111.1)
3.500"
(88.9)
SB031028
SB031029
480
MT020020
4.875"
(123.8)
4.000"
(101.6)
SB031036
535
MT020021
All specifications are subject to change without notification. Dimensions are in inches; millimeters are in parentheses.
Right (Standard)*
* Standard Lead exit – 60" (1.52m) wrapped - 600 volt leads; right angle lead exit; and 6" (15.2cm) stainless steel, square-lock armored cable.
Mold Power-Thermocouple Input Connector A Single-Zone Power-Thermocouple Input Connector is available for mounting in or on the mold to accept the power- thermocouple cable from the mainframe. The water-resistant connector has an integral retaining latch for a secure cable connection and numbered screw-type terminals for power
ITEM NUMBER CKPTIC1
Recommended Mold Pocket Layout For Mold Power-Thermocouple Input Connector (CKPTIC1)
and thermocouple lead wires. *Can be mounted on top of mold
3.50
1.50
1.36
0.91 0.46 0.32
0.14
REF
Armored Mold Power-Thermocouple Cables Single-Zone Mold Power-Thermocouple Cables are constructed of special lead wire for use in high temperature environments, and are available to connect the mainframe to the input connector on the mold. Available in lengths of 10 or 20 feet. Integral retaining latches on the mainframe and mold connections provide secure cable connections. Connector configurations ensure proper insertion of cable.
ITEM NUMBER MPTC10 MPTC20
2.00
1.45
1.00
NO. 4-40 NC-2B TAP .50 DEEP MIN. (2) PLACES 0.25 R
0.55
0.25R
1.180
MOLD SURFACE
0.90
REF
MOUNTING SURFACE
2.00
4.00 MIN.
For complete information on temperature controls, please see DME Control Systems Catalog.
U.S. 800-626-6653 n Canada 800-387-6600 n DME.net n store.DME.net