WeldStation Aire User & Maintenance Manual

B RINGING THE W ELD S TATION A IRE , N O L IFTING T OOL NOTE: Please be sure the chain hoist, come along, or chain/cable, is rated for that amount of weight to be lifted. Properly sized chain or cable can be attached to header bar on a fork lift truck. The chain or cable can then be

connected to the lifting lugs of the unit. The forklift truck can then be used to lift and move the unit. Other methods include attaching a chain hoist or come along, or both to the eyelets provided at the top of the unit. When the unit is being lifted, the bottom of the unit may shift. If possible, brace the

bottom of the unit to prevent slipping. A '2 x 4' brace is fastened to the front floor flanges of the booth. This is used during shipment to prevent the collapse of the booth side walls. This '2 x 4' should be kept in place while bringing the unit upright to prevent damage. SLOWLY hoist the unit up, supporting it whenever and wherever possible.

DO NOT let the unit slam suddenly when bringing the unit into the upright position. This can cause damage to the unit. If risers are being used, then attach the risers before bringing the unit upright.