Marine Sunroof Catalog Webasto Product Range & Reference List
eBTM 2.0
Battery Thermal Management
PLUG & PLAY
COMPACT
& POWERFUL
STAND ALONE
Universal plug & play thermal management solution for traction battery packs
Ensures ideal battery performance and prolongs service life
Traction batteries will only function perfectly in narrow temperature ranges:
Battery cells do not deliver the desired output when cold and may degrade over time when too hot. eBTM 2.0 monitors the current temperature and actively balances between cooling and heating circuits, thus always hitting the “sweet spot”.
10 kW
R-1234yf refrigerant
400/800V wide range of voltages
500g of refrigerant for low GWP
8 kW cooling
12/24 V compatible
Low energy output
Recommended battery temperature
Battery cell aging
eBTM heating
eBTM cooling
T bat [°C]
-25
0
25
35
55
Stand-alone Battery Thermal Management Unit
Cooling Provides optimal cooling when battery packs are under stress or used during hot weather conditions
Pre-Conditioning Sets the perfect temperature for battery cells during charging phases or before operation
Heating Delivers heat during extremely cold ambient conditions
Balancing Adjusts the temperature dynamically during different driving phases
6x Battery packs Entirely scalable system
Versatile and suitable for every application eBTM 2.0 is a precisely tuned system solution for light commercial vehicles, busses, trucks, construction and agricultural vehicles. It is also a perfectly scalable solution: Starting with just one unit, every type of electrical vehicle can be equipped with one or several battery cooling units.
3
Technical specifications
eBTM 2.0 400 VDC
eBTM 2.0 800 VDC
Functional Information
8 kW 7 kW
Maximum cooling power Maximum heating power Maximum coolant flow Nominal coolant flow Pressure level outlet eBTM Ambient temperature range
8 kW
10 kW
60 l/min 52 l/min 0.5 barA
60 l/min 54 l/min 0.5 barA
- 35 ... 50°C
- 35 ... 50°C
Electronical Information
High Voltage
366 VDC
Nominal high voltage supply High voltage operating range High voltage undervoltage limit High voltage overvoltage limit
675 VDC
300 VDC - 432 VDC
500 VDC - 850 VDC
200 VDC 450 VDC
450 VDC 865 VDC 10.5 kW
Maximum heating power consumption Maximum cooling power consumption Min Isolation Resistance (@ 1000 VDC ) Max discharge time (HV < 60 VDC)
7.5 kW
6 kW
6 kW
500 k Ω
500 k Ω
3s (@ 432 VDC) 1900 VAC for 60s
45s (@ 850 VDC) 1900 VAC for 60s
Max Voltage withstand Maximum voltage rise
40 V/ms
100 V/ms
Cx - Capacity Cy - Capacity
55 µF 70 nF
67 µF 70 nF
High voltage connector (eBTM)
Amphenol ELR2A02 Amphenol ELP2A02
Amphenol ELR2Y02 Amphenol ELP2Y02
High voltage connector (Counterpart)
Comunication / Low Voltage
Communication with VIB
CAN BUS 2.0B / CAN J1939
CAN BUS 2.0B / CAN J1939
Baudrate
250 kbps / 500 kbps
250 kbps / 500 kbps
Low Voltage power in operating modes
50 W
50 W
12 VDC : 9 VDC - 16 VDC 24 VDC : 18 VDC - 32 VDC 0.6 W (50 mA @ 12 VDC) 0.24W (10 mA @ 24 VDC) FCI HCCMHPE24BKAFSV FCI 211PC249S0053
12 VDC : 9 VDC - 16 VDC 24 VDC : 18 VDC - 32 VDC 0.6 W (50 mA @ 12 VDC) 0.24W (10 mA @ 24 VDC) FCI HCCMHPE24BKAFSV FCI 211PC249S0053
Nominal low voltage range
Max. low voltage power in sleep mode
Communication connector (eBTM)
Communication connector (Counterpart)
General Information
Dimensions L x W x H
1000 mm x 700mm x 300mm
Compressor
Scroll
Protection IP degree
IP66
Weight
91 kg
Installation position
Roof / Chassis
Refrigerant
R-1234yf
Refrigerant charge
500 g
Battery fluid
Water/Ethylene Glycol mix at 50-50%
Storage temperature range [°C]
- 40 ... 70°C
Internal coolant circuit
3 l
External coolant circuit (eBTM share of liquid)
3.4 l + 0.75 l
Hydraulic connector (eBTM)
NORMAQUICK PS3 NW20
NORMAQUICK PS3 NW20
Low voltage power supply needed
internal DC/DC installed
Webasto Thermo & Comfort North America, Inc. 15083 North Road Fenton, Michigan 48430 USA
Toll Free: 800-860-7866 Phone: 810-593-6000 webasto-electrified.com