maxon Product Range 2024/25

Explanations of maxon terminology EC motor Dimensional drawings Presentation of the views according to the projection method E (ISO). All dimensions in [mm]. Motor Data The values in lines 2 – 15 are valid when using block commutation. 1 Nominal voltage U N [Volt] 13

Speed constant k n [rpm/V] indicates the theoretical no load speed per volt of applied voltage, disregarding friction losses. 14 Speed/torque gradient D n / D M [rpm/mNm] The speed/torque gradient is an indicator of the motor’s performance. The smaller the value, the more powerful the motor and consequently the less motor speed varies with load variations. It is based on the quotient of ideal no load speed and ideal stall torque (tolerance ± 20%). The real characteristic curve depends on the speed for EC motors with slotted winding (EC flat and EC-i); it is steeper at high speeds and flatter at slow speeds. The real gradient at nominal voltage can be approxi- mated by a straight line between no load speed and the nominal operating point (see page 81). 15 Mechanical time constant t m [ms] is the time required for the rotor to accelerate from standstill to 63% of its no load speed. 16 Rotor moment of inertia J R [gcm2] is the mass moment of inertia of the rotor, based on the axis of rotation. 17 Thermal resistance housing-ambient R th2 [K/W] and 18 Thermal resistance winding-housing R th1 [K/W] Characteristic values of thermal contact resistance without additional heat sinking. Lines 17 and 18 com- bined define the maximum heating at a given power loss (load). Thermal resistance R th2 on motors with metal flanges can decrease by up to 80% if the motor is coupled directly to a good heat-conducting (e.g. metallic) mounting rather than a plastic panel. 19 Thermal time constant winding t w [s] and 20 Thermal time constant motor t s [s] These are the typical reaction times for a temperature change of winding and motor. It can be seen that the motor reacts much more sluggishly in thermal terms than the winding. The values are calculated from the product of thermal capacity and given heat resistanc- es. 21 Ambient temperature [°C] Operating temperature range. This derives from the heat reliability of the materials used and viscosity of bearing lubrication. 22  Max. winding temperature [°C] Maximum permissible winding temperature. 23 Max. speed n max [rpm] is the maximum recommended speed based on ther- mal and mechanical perspectives. A reduced service life can be expected at higher speeds. 24 Axial play [mm] On motors that are not preloaded, these are the tole- rance limits for the bearing play. A preload cancels out the axial play up to the specified axial force. When load is applied in the direction of the preload force (away from the flange), the axial play is always zero. The length tolerance of the shaft includes the maxi- mum axial play. 25 Radial play [mm] Radial play is the bearing’s radial movement. A spring is utilized to preload the motor’s bearings, eliminating radial play up to a given axial load.

26/27 Max. axial load [N] Dynamic: axial loading permissible in operation. If dif- ferent values apply for traction and thrust, the smaller value is given. Static: maximum axial force that does not cause per- manent damage when applied to the front of the shaft at standstill. Shaft supported: maximum axial force applying to the shaft at standstill if the force is not input at the other shaft end. This is not possible for motors with only one shaft end. 28 Max. radial load [N] The value is given for a typical distance from the front flange. As the distance increases, this value decreas- es. 29 Number of pole pairs Number of north poles of the permanent magnet. The phase streams and commutation signals pass through per revolution p cycles. Servo-controllers require the correct details of the number of pole pairs. 30 Number of phases All maxon EC motors have three phases. 31 Weight of motor [g] 32 Typical noise level [dBA] Is the statistical average of the noise level measured in accordance with the maxon standard (10 cm dis- tance radially to the drive, no-load operation at a cer- tain speed. The drive lies freely on a plastic foam mat in the noise chamber). The acoustic noise level depends on a number of fac- tors, such as component tolerances, and it is greatly influenced by the overall system in which the drive is installed. When the drive is installed in an unfavo- rable constellation, the noise level may be significantly higher than the noise level of the drive alone. The acoustic noise level is measured and determined during product qualification. In manufacturing, a struc- ture-borne noise test is performed with defined limits. Impermissible deviations can thus be identified. 33 Max. torque M max [mNm] Maximum torque the motor can briefly deliver. It is limited by the overload protection of the electronics. 34 Max. current I max [A] Surge current with which the peak torque is generated at nominal voltage. With an active speed controller, surge current is not proportionate to the torque, but also depends on the supply voltage. As a result, this value only applies at nominal voltage. 35 Type of control «Speed» means that the drive is fitted with an integral speed controller. «Controlled» means that the drive is fitted with true commutation electronics. 36 Supply voltage +V CC [V] Range of supply voltages measured in respect of GND at which the drive functions. 37 Speed set value input U C [V] Range of analog voltage for set speed value mea- sured in respect of GND. For 2 wire solutions, the supply voltage acts as speed setting at the same time. 38 Scaling Set speed value input k c [rpm/V] Set speed value n c is based on the product n c = k c · U c . 39 Speed range Achievable speeds in the controlled range. 40 Max. acceleration The set speed value follows a sudden set point change with a ramp. This value indicates the increase in the ramp.

is the applied voltage between two powered phases in block commutation. See page 64 for the timing diagram of the voltage in the three phases. All nominal data (lines 2 – 9) refer to this voltage. Lower and higher voltages are permissible, provided that limits are not exceeded. 2 No load speed n 0 [rpm] ±10% is the speed at which the unloaded motor runs with the nominal voltage applied. It is approximately pro- portional to the applied voltage. 3 No load current I 0 [mA] ±50% This is the typical current that the unloaded motor draws when operating at nominal voltage. It increas- es with rising speed owing to bearing friction and iron losses. No load friction depends heavily on tempera- ture. It decreases in extended operation and increas- es at lower temperatures. 4 Nominal speed n N [rpm] is the speed set for operation at nominal voltage and nominal torque at a motor temperature of 25°C. 5 Nominal torque M N [mNm] is the torque generated for operation at nominal voltage and nominal current at a motor temperature of 25°C. It is at the limit of the motor’s continuous operation range. Higher torques heat up the winding too much. 6 Nominal current I N [A] is the current in the active phase in block commuta- tion that generates the nominal torque at the given nominal speed (= max. permissible continuous load current). The maximum winding temperature is reached at 25°C ambient temperature in continuous operation with I N . I N decreases as speed increases due to additional losses in the lamination. 7 Stall torque M H [mNm] is the linearly calculated load torque for motors that causes the shaft to stall at nominal voltage. With EC-flat and EC-i motors, this torque often cannot be achieved due to saturation effects. 8 Stall current I A [A] is the quotient from nominal voltage and the motor’s terminal resistance. Stall current is equivalent to stall torque. With larger motors, I A cannot often be reached due to the amplifier’s current limits. 9 Max. efficiency h max [%] is the optimal relationship between input and out- put power at nominal voltage. It also doesn’t always denote the optimal operating point. 10 Terminal resistance phase to phase R [Ω] is determined by the resistance at 25°C between two connections of the default configuration. 11 Terminal inductance phase to phase L [mH] is the winding inductance between two connections. It is measured at 1 kHz, sinusoidal. 12 Torque constant k M [mNm/A] This may also be referred to as «specific torque» and represents the quotient from generated torque and applicable current.

188 maxon EC motor 

© 2024 maxon. All rights reserved. April edition. Subject to change.

Made with FlippingBook Publishing Software