maxon Product Range 2024/25

EC 45 flat ∅ 42.8 mm, brushless, 12 watt

A with Hall sensors

B sensorless

M 1:2

Stock program Standard program Special program (on request)

Part Numbers

A with Hall sensors B sensorless

200188

339275

339276

200141

339277

339278

Motor Data

Values at nominal voltage 1 Nominal voltage 2 No load speed 3 No load current 4 Nominal speed 5 Nominal torque

9

9

12

12

24

24

V

8000 147 4780 23.8 2.04 92.6 8.9 77

7980 147 4540 23.6 2.04 80.6 7.75 75

8160 115 4840 20.1 1.37 70.8 5.24 73 2.29 0.541 13.5 706 120 65.5 52.3

8150 115 4720 20 1.37 66.5 4.92 2.44 0.541 13.5 706 128 69.8 52.3 73

7310 47.6 4390 0.766 114 3.74 27

7300 47.6 4360 27.1 0.768 112 3.67

rpm mA rpm mNm mNm A A

6 Nominal current (max. continuous current)

7 Stall torque1 8 Stall current 9 Max. efficiency

%

79

79

Characteristics 10 Terminal resistance phase to phase 11 Terminal inductance phase to phase

Ω

1.01 0.32 10.4 918 89.3 48.9 52.3

1.16 0.32 10.4 918 103 56.1 52.3

6.42 2.75 30.5 313 65.9 36.1 52.3

6.54 2.75 30.5 313 67.1 36.8 52.3

mH

12 Torque constant 13 Speed constant 14 Speed/torque gradient 15 Mechanical time constant

mNm/A rpm/V rpm/mNm

ms gcm2

Specifications 16 Rotor inertia

Operating Range

Comments

Thermal data 17 Thermal resistance housing-ambient 18 Thermal resistance winding-housing

n [rpm]

Continuous operation In observation of above listed thermal resistance (lines 17 and 18) and an ambient temperature of 25°C, the maximum permissible winding temperature will be reached during continuous operation = thermal limit. Short term operation The motor may be briefly overloaded (recurring). Assigned power rating

   

6.59 K/W 5.56 K/W 8.36 s 188 s +125°C -40…+100°C 0 mm 10000 rpm typ. 0.6 mm preloaded

12 W

  19 Thermal time constant winding 20 Thermal time constant motor 21 Ambient temperature 22 Max. winding temperature Mechanical data (preloaded ball bearings) 23 Max. speed

2000 4000 6000 8000 10000

200188

24 Axial play at axial load 25 Radial play 

< 5.0 N > 5.0 N

   26 Max. axial load (dynamic) 27 Max. force for press fits (static) (static, shaft supported)  28 Max. radial load, 15 mm from flange Other specifications 29 Number of pole pairs 30 Number of phases 31 Weight of motor Values listed in the table are nominal. Connection with Hall sensors sensorless Pin 1 V Hall 4.5…18 VDC Motor winding 1 Pin 2 Hall sensor 3* Motor winding 2 Pin 3 Hall sensor 1* Motor winding 3 Pin 4 Hall sensor 2* neutral point Pin 5 GND Pin 6 Motor winding 3 Pin 7 Motor winding 2 Pin 8 Motor winding 1 *Internal pull-up (7…13 kΩ) on V Hall Wiring diagram for Hall sensors see p. 67 Adapter Part number Part number see p. 579 220300 220310 Connector Part number Part number TE 1-84953-1 84953-4 Molex 52207-1133 52207-0433 Pin for design with Hall sensors: FPC, 11-pol, Pitch 1.0 mm, top contact style 1 Calculation does not include saturation effect (p. 81/188)    

4.8 N 45 N 1000 N 12.5 N

30

M [mNm] I [A]

20

10 1.0

2.0

4.0

3.0

8 3

Modular System

Details on catalog page 54

57 g

Motor Control 547_DEC Module 24/2 550_ESCON Module 24/2 551_ESCON 36/3 EC 551_ESCON Module 50/4 EC-S 561_EPOS4 Micro 24/5 562_EPOS4 Module 24/1.5 562_EPOS4 Module 50/5 563_EPOS4 Compact 24/5 3-axes 564_EPOS4 Compact 24/1.5 565_EPOS4 Compact 50/5 567_EPOS4 50/5

maxon EC motor 319

© 2024 maxon. All rights reserved. April edition. Subject to change. 