maxon Product Range 2026/27

GPX 32 ∅ 32 mm, planetary gearhead

M 1:2 Key data

LN Noise reduced

LZ Backlash reduced

Max. transmittable power Max. continuous torque Max. continuous input speed Ambient temperature

W

80

50

Nm rpm

4

5

8000

8000

°C

-40…+100 Ball bearing

-40…+100 Ball bearing

Bearing at output Typical noise level

dBA -5 compared to standard configuration

Operating range (output shaft)

LN Noise reduced

LZ Backlash reduced

n [rpm]

n [rpm]

Continuous operation Intermittent operation

10000

10000

1000

1000

1 stage

2 stages

2 stages

100

100

3 stages

3 stages

10

10

1

1

0.1

1

10 M [Nm]

0.1

1

10 M [Nm]

Specifications

LN Noise reduced

LZ Backlash reduced

Number of stages Max. transmittable continuous power Max. transmittable intermittent power Max. continuous torque Max. intermittent torque Max. continuous input speed Max. intermittent input speed Average backlash no load Max. efficiency Max. axial load (dynamic) Max. radial load, 10 mm from flange

1

2

3

2

3

W W

80 100 1.00 1.30 6000 7500 0.55 90 110 160 26.7 140

40 50

20 25

50 62

25 31

Nm Nm rpm rpm

2.30 2.90 7000 78 0.7 110 180 36.3 185

4.00 5.00 8000 75 0.9 110 180 43.9 230

2.90 3.60 7000 78 0.55 110 180 36.3 185

5.00 6.25 8000 75 0.75 110 180 43.9 230

8750 10 000

8750 10 000

%

°

N N

Gearhead length L11

mm

Weight

g

Configuration Number of stages Reduction

LN Noise reduced

LZ Backlash reduced

1

2

2

3

3

X:1

16, 21, 26, 28, 35

3.9, 5.3 16, 21, 26, 28, 35

62, 83, 103, 111, 138, 150, 172, 186, 231

62, 83, 103, 111, 138, 150, 172, 186, 231

Absolute reduction: (see online)

Version Flange Shaft

Standard/ceramic version/noise reduced/backlash reduced/high power/ultra performance

Standard flange/configurable flange Length/diameter/flat face/cross hole

Modular system DC Motors



Page 

Page

№ of stages [opt.] 

ECX FLAT 32 S IE* ECX FLAT 32 L IE* ECX PRIME 30 L ECX FLAT 32 S* ECX FLAT 32 L* BLDC Motors

№ of stages [opt.]

DCX 26 L DCX 32 L

3 285–286 3 299–300 287

1–2 [3] 1–2 [3] 1–2 [3] 1–2 1–2 [3]

135 136 190

1–2 [3]

DC-max 26 S*

218–220 221–222

*Limited selection of reduction ratios (see online). ¹This length may vary depending on the configuration and choice of motor. The effective length is calculated at the end of the configuration process.

maxon 361

© 2026 maxon. All rights reserved. April edition. Subject to change. 