IDX 56 L 56 mm, with integrated electronics IP65 drive with Positioning/Speed Controller Key Data: 280/316 W, 795 mNm, 6000 rpm
M 1:2
Drive data (provisional) Nominal power supply voltage Nominal speed Nominal torque at 25°C Nominal torque at 40°C Nominal supply current at 25°C Nominal supply current at 40°C Maximum speed at nominal voltage Maximum permissible drive speed Maximum torque (short-time) Maximum supply current (short-time) Rotor inertia of the drive Nominal supply voltage + V CC Mechanical time constant Thermal resistance housing-ambient Thermal resistance winding-housing Thermal time constant winding Thermal time constant drive Ambient temperature Thermal data
V
1_ 2_ 3_ 4_ 5_ 6_ 7_ 8_ 9_
24
48
rpm mNm mNm rpm rpm mNm A A
2724 795 690 11.4 9.9 3110 6000 1589 24 265
3500 779 690 4925 5000 2006 6.7 6.0
10_ 11_ 12_ 13_ 14_ 15_ 16_ 17_ 18_
24
A V
265 12..48 12..48 0.57 0.55
gcm²
ms
Operating Range n [rpm] 24-V-system
K/W K/W
2.01 0.76 20.1 1450 -30…+85
280 W
s s
6000 5000 4000 3000 2000 1000 0
°C
Mechanical data Axial play Direction of force Radial play Preload
mm
19_
0.14 16 Pull
N
1500 M [mNm]
0
500
1000
12 150 110 [12.5] preloaded 1445 58 [4000] IP65
20_ 21_ 22_ 23_
Max. axial load (dynamic) Max. force for press fits (static) Max. radial load [mm from flange]
N N N
n [rpm] 48-V-system
280 W
6000 5000 4000 3000 2000 1000 0
Other specifications Weight of the drive Typical noise level [rpm]
g
24_ 25_
dBA
Continuous operation Continuous operation with reduced thermal resistance R th2 50% Short term operation
Protection class without shaft Sensor ENC single-turn absolute encoder: resolution, bits EMT multi-turn absolute encoder: resolution, bits Multi-turn: max. no. of turns Supply
M [mNm]
0
500
1000
1500
12
Gear 410_GPX 52 A/UP 411_GPX 52 LN Modular System
Details on catalog page 42
Sensor integrated ENC integrated EMT Accessories 589_Brake AB 42 S
Motor Control integrated
Stages [opt.]
14 65 536
1–3 1–3
462_GB 80 463_GB 12
1 1
M12, male, 5 poles, L-coded M12, male, 12 poles, A-coded M8, male, 5 poles, B-coded M8, female, 5 poles, B-coded M8, female, 4 poles, A-coded M8, female, 4 poles, A-coded
I/O‘s
CANopen Input CANopen Output EtherCAT Input EtherCAT Output
Compatible cables available online in the configurator
Configuration
Flange front: A-Flange / C-Flange Interface with Positioning / Speed Controller: CANopen / EtherCAT Interface with Speed Controller: I/O Shaft: standard/short
maxon compact drive 363
© 2024 maxon. All rights reserved. June edition. Provisional data. Subject to change.
Made with FlippingBook Publishing Software