GPX 16 HP ∅ 16 mm, planetary gearhead Sterilizable
NEW
M 1:1
Key Data
16.0 0.8 14000 -10 … +135 Ball bearing With shaft seal
Max. transmittable power Max. continuous torque Max. continuous input speed Ambient temperature Bearing at output
W
Nm rpm
°C
Operating Range (output shaft)
With shaft seal
n [rpm]
Continuous operation Intermittent operation
10000
1000
Sterilization information With shaft seal: typically 2000 autoclave cycles Sterilization with steam Temperature 134°C ± 4°C Compression pressure up to 2.3 bar Rel. humidity 100% Cycle length 18 minutes
1 stage
2 stages
100
3 stages
10
1
0.01
0.1
1 M [Nm]
Specifications
With shaft seal
1
2
3
Number of stages Max. transmittable continuous power Max. transmittable intermittent power Max. continuous torque Max. intermittent torque Max. continuous input speed Max. intermittent input speed Average backlash no load Max. efficiency Max. axial load (dynamic) Max. radial load, 5 mm from flange Gearhead length L11
W W
16.0 20.0 0.40 0.55
8.0 10.0 0.55 0.70
4.0 4.4 0.80
Nm Nm rpm rpm
1.0 12 000 12 000 14 000 15 000 15 000 17 500 85 75 65 1.0 1.2 1.3 30 30 30 25 35 35 27.8 34.7 39.7 36 43 48
%
°
N N
mm
Weight
g
Configuration Number of stages Reduction
With shaft seal
1
2
3
X:1
3.9, 5.3, 6.6 16, 21, 26, 28, 35, 44
62, 83, 103, 111, 138, 150, 172, 186, 231
Absolute reduction: (see online)
Version Flange Shaft
Shaft seal Standard flange
Length/flat face/cross hole
EC motor ECX SPEED 16 M ECX SPEED 16 L ECX PRIME 16 STE* Modular System
Page
№ of stages [opt.]
1–3 208–209 1–3 212–213
1–3
235
*Limited selection of reduction ratios (see online). ¹This length may vary depending on the configuration and choice of motor. The effective length is calculated at the end of the configuration process.
388 maxon gear
© 2024 maxon. All rights reserved. June edition. Provisional data. Subject to change.