maxon Product Range 2026/27

ENX 22 EMT Encoder ∅ 22 mm, 65 536 turns, Multi Turn 131 072 steps, Single Turn

Key data

EMT absolute differential

Multi-turn: max. no. of turns Multi-turn: resolution Single-turn: steps per turns Single-turn: resolution Encoder length L¹ Ambient temperature

65 536 16 131 072 17 22.7 -40...+105 25

bits bits mm °C

Weight

g

Selection criteria

EMT absolute differential

Multi-turn detection Detection of speed and rotation direction

Speed and position control Compact and robust design High resolution Economical

suitable

suitable to a limited extent

not suitable

Specifications Supply voltage V CC Typical current draw  Max. speed Data encoding Min. clock frequency CLK Max. clock frequency CLK Setup time after Power On Timeout

EMT for DCX, ECX PRIME and EC-i

EMT integrated into IDX

V

5 ±0.5 12 000 Binary 90

5 ±0.5 12 000 Binary 90

mA rpm MHz MHz

BiSS-C: 0.08 BiSS-C: 5 BiSS-C: 18

SSI: 0.3 SSI: 1 SSI: 7

BiSS-C: 0.08 BiSS-C: 5 BiSS-C: 18 Max. 0.1

SSI: 0.3 SSI: 1 SSI: 7

µs

s Max. 0.1

Moment of inertia of pulse disk Plug manufacturer JST Plug type no. BM08B-NSHSS -TBT Matching connector type no. NSHR-08V-S

gcm2

≤1.55

≤1.55

Pin 1 GND Pin 2 do not connect Pin 3 do not connect Pin 4 Data+ / SLO+ Pin 5 Data- / SLO- Pin 6 CLK- / MA- Pin 7 CLK+ / MA+ Pin 8 V CC

Pin 1 GND Pin 2 Motor NTC Pin 3 +V CC

1

Pin 9 Motor NTC Pin 11 Data- / SLO- Pin 12 Data+ / SLO+ Pin 13 CLK+ / MA+ Pin 14 CLK- / MA- Other pins not connected

8

Output signals: EIA standard RS422 Output current per channel: ±20 mA

Output signals: EIA standard RS422 Output current per channel: ±20 mA

Configuration Signal protocol

EMT absolute differential

BiSS-C, SSI

Modular system Servo Motors

Page Dimensions of standard configuration

M 1:2 Additional information

Additional length: IDX 56 +20 mm IDX 70 +39 mm

¹ The length shown here refers to the encoder. An additional intermediate plate is required for motor mounting. For more detailed information, see the combined dimensional drawing. EC motors: The angle value 0 is calibrated to the commutation phase of coil 1 (equates to Hall signal 1 for motors with Hall sensors, block commutation), see p. 73. Ordering information: For motors that cannot be con- figured online, the part numbers 711113 (BiSS-C) and 711112 (SSI) must be used when ordering.

IDX 56 IDX 70

119–121 122–124

DCX 22 DCX 26 L DCX 32 L DCX 35 L DC Motors

281–284 285–286

287 288

ECX PRIME 22 M ECX PRIME 22 L ECX PRIME 30 L BLDC Motors

186 188 190

EC-i 30 EC-i 40 EC-i 52 EC-i 70

197–200 201–206 207–208

Connecting cable 300 mm for EMT to EPOS4 708590

Further technical details can be found in the product information in the online shop under Downloads.

209



438 maxon



© 2026 maxon. All rights reserved. April edition. Subject to change.

Made with FlippingBook Publishing Software