ENX 22 MILE Encoder ∅ 22 mm, 1024 CPT Integrated into motor
Key data
ENX 22 MILE incremental
Number of channels Max. counts per turn Encoder length L Ambient temperature
2 1024 1.2 -40…+100 8
mm °C
Weight
g
Selection criteria
ENX 22 MILE incremental
Speed and rotation direction detection Speed and position control Compact and robust design
High resolution Cost effective
suitable
suitable to a limited extent
not suitable
Specifications Supply voltage V CC Typical current draw Max. operating frequency
ENX 22 MILE incremental
V
5V ±10% 15 1000 14 000
mA kHz rpm
Max. speed Connector
10-pin 2.54 mm multipoint connector (IEC/EN 60603-13 / DIN41651) Pin 1 not connected Pin 2 V CC Pin 3 GND Pin 4 not connected
1
9
2
Pin 5 channel A Pin 6 channel A Pin 7 channel B Pin 8 channel B Pin 9 not connected Pin 10 not connected
10
EC FLAT ECX FLAT 22 S ECX FLAT 22 L modular system
Page Dimensions standard version
M 2:3
253 254 255
ECX FLAT 22 S High Torque
494 maxon sensor
© 2024 maxon. All rights reserved. August edition. Provisional data. Subject to change.