Encoder HEDL 9140 500 CPT, 3 channels, with line driver RS 422
Cycle C = 360°e
Pulse P = 180°e
U High U Low U High U Low U High U Low
Channel A
90°e
Phase shift
Channel B
Channel I
(Index)
s 3
s 4
s 1
s ∆ 45°e < s 2 s = 90°e 1..4
Direction of rotation cw (definition cw p. 90)
Stock program Standard program Special program (on request)
Part numbers
cable outlet axial cable outlet radial
386051 386053
386001 386002
Type
Counts per turn Number of channels Max. operating frequency (kHz) Max. speed (rpm)
500 100 3
500 100 3
12 000
12 000
overall length
overall length
Modular system + Motor
+ Gearhead
+ Brake Page
Page
Page
Overall length [mm] / • see Gearhead
RE 50, 200 W 164
170.4
RE 50, 200 W 164 GP 52, 4 - 30 Nm 443 RE 50, 200 W 164 GP 62, 6.2 - 38.5 Nm 445
• • • •
RE 50, 200 W 164
AB 44 592
183.4
RE 50, 200 W 164 GP 52, 4 - 30 Nm 443 AB 44 592 RE 50, 200 W 164 GP 62, 6.2 - 38.5 Nm 445 AB 44 592
RE 65, 250 W 165 RE 65, 250 W 165
187.5 205.5 •
RE 65, 250 W 165 GP 81, 15.4 - 92.3 Nm 446
AB 44 592
RE 65, 250 W 165 GP 81, 15.4 - 92.3 Nm 446 AB 44 592
•
Technical data Supply voltage V CC Typical current draw Output signal driver used: Phase shift Φ
Pin allocation Encoder Cable white = Cable brown = Cable green = Cable yellow =
Connection example
5 V ± 10% 55 mA DS26LS31 90°e ± 45°e
Line receiver Recommended IC's:
GND V CC
V CC 5 VDC Channel A Channel A GND Channel B Channel B
EIA Standard RS 422
- MC 3486 - SN 75175 - AM 26 LS 32
Cable grey Cable pink Cable blue Cable red
= = = =
Channel A
Signal rise time (typically, at C L = 25 pF, R L = 11 k Ω , 25 °C) Signal fall time (typically, at C L = 25 pF, R L = 11 k Ω , 25 °C)
R
Channel I (Index) Channel I (Index)
180 ns 40 ns 90°e
Channel A
Cable size 8 × 0.25 mm 2 Motor Cable white = Cable brown = Cable size 2 × 1.0 mm 2
Channel B
Index pulse width Operating temperature range Moment of inertia of code wheel Max. angular acceleration Output current per channel
R
Motor + Motor -
-40…+85 °C ≤ 0.6 gcm 2 250 000 rad s -2
Channel B
Channel I
R
± 20 mA
Channel I
Protection to
IP54
The index signal I is synchronized with channel A or B.
Terminal resistance R = typical 120 Ω
maxon sensor 541
© 2025 maxon. All rights reserved. February edition. Subject to change.
Made with FlippingBook Publishing Software