GENERATION 2020 INTELECT ® RPW 2
GENERATION 2020 INTELECT ® RPW 2
With 10 years of experience and 10,000 RPW devices sold all over the world Chattanooga® has learned a lot about what really matters to you and your patients and integrated it into our next generation clinical Radial Pressure Wave unit. Smart Bluetooth module and the Intelect Connect App give the Intelect® RPW 2 device the ability to download data, produce reports and upload treatment data to additional devices within the practice. The Intelect Connect App will allow patient data to be collected and share between all Intelect Connect ready devices. The new Intelect® RPW 2 combines streamlined design with ergonomics and patient-comfort with ease-of-use resulting into the most compact clinical unit currently on the market. With “made in Germany & the USA” as a quality label we are proud to offer you the latest technology in a device you can trust!
KEY FEATURES
NEW FALCON® HANDPIECE allowing lower Bar pressures for an increased range of indications and applicators.
LARGE GRAPHIC COLOR TOUCH SCREEN High resolution 7” capacitive touch screen for greater customer experience.
SUGGESTED PROTOCOLS LIBRARY Available at a finger click; treatment pictures, anatomical and pathological library, treatments guidelines.
COMFORT MODE Unique automatic energy ramp up designed to provide better patient comfort.
V-ACTOR® HF* Vibration frequency up to 50Hz for Vibration therapy and muscle relaxation.
LARGE CHOICE OF TRANSMITTERS* 17 different transmitters available for tendinopathies, trigger points, spine and fascia treatments.
EASY FIT FOR EVERY TREATMENT ROOM
Slim design 41x42x110cm (LxWxH), not a lot of space needed for this new RPW generation.
WINDOWS 10 APP The Intelect Connect App* gives great flexibility in the handling and processing patient data, allowing the export of patient treatment data and protocols from device to PC allowing not only the ability to produce reports but also to share treatments and patient data between multiple Intelect RPW 2 devices within a practice and in
other smart enabled Chattanooga devices. Download the Intelect Connect App free from www.chattanoogarehab.com
* Optional accessories
FALCON®, V-ACTOR®, SPINE-ACTOR®, and PERI-ACTOR® are registered trademarks of Storz Medical AG
TARGETED PAIN RELIEF
The Intelect® RPW 2 allows for the treatment of indications with radial, pneumatically-generated, low-energy acoustic waves, or ‘pressure pulses’. The applied pressure pulse propagates radially within the tissue, generating a therapeutic effect.
The V-ACTOR® HF optional hand piece allows mechanical vibration, for vibration massage.
INDICATIONS • ACHILLES TENDINOPATHY (1) • DISORDERS OF TENDONS INSERTIONS (2) • MYOFASCIAL TRIGGER POINTS (3) • PAIN & INFLAMMATION IN ORTHOPAEDIC CONDITIONS (4) • PLANTAR FASCIITIS (5) • PULSE VIBRATION MASSAGE (6)
RECOMMENDED TREATMENT GUIDELINES • LOCALIZE THE PAINFUL AREAS YOU PLAN TO TREAT • SELECT MOST APPROPRIATE TRANSMITTERS BASED ON TREATMENT GOAL AND TARGETED TISSUE • APPLY ULTRA SOUND WATER BASED GEL ON THE SKIN OVERLYING THE TREATMENT AREA • ALWAYS START WITH LOWER LEVEL OF INTENSITY • PERFORM A POST-TREATMENT TEST TO SEE FOR BETTER FUNCTION AND DECREASED IN PAIN
As a result of clinical evidence, most treatment protocols are based on 5 to 10 sessions of 1,500-2,500 shocks.
FALCON®, V-ACTOR®, SPINE-ACTOR®, and PERI-ACTOR® are registered trademarks of Storz Medical AG
EDUCATION Access to an online education platform and scientific research library is offered to every Chattanooga® Intelect® RPW 2 user.
CLINICAL INFORMATION
1. Gerdesmeyer L. Current evidence of extracorporeal shock wave therapy in chronic Achilles tendinopathy.NCBINCBI Logo Int J Surg. 2015 Dec;24(Pt B):154-9. doi: 10.1016/j.ijsu.2015.07.718. Epub 2015 Aug 29.”
2. Gerdesmeyer L. Current evidence of extracorporeal shock wave therapy in chronic Achilles tendinopathy.NCBINCBI Logo Int J Surg. 2015 .
3. Nedelka T.Mechano-transduction effect of shockwaves in the treatment of lumbar facet joint pain.Neuro Endocrinol Lett. 2014
4. Schmitz C. Efficacy and safety of extracorporeal shock wave therapy for orthopedic conditions: a systematic review on studies listed in the PEDro database.Br Med Bull. 2015;116:115-38. doi: 10.1093/bmb/ldv047. Epub 2015 Nov 18.
5. Ogden JA. Shockwave therapy for chronic proximal plantar fasciitis: a meta-analysis.Foot Ankle Int. 2002 Apr;23(4):301-8
6. S. Broadbent, JJ. Rousseau, RM. Thorp, SL. Choate, FS. Jackson, DS. Rowlands. Vibration therapy reduces plasma IL6 and muscle soreness after downhill running. 2010 Sep;44(12):888-94
INTELECT® RPW 2 TRANSMITTERS
A choice of standard transmitters for Radial Pressure Wave (RPW) indications. Each transmitter is unique by shape and material to deliver it’s own energy flux density and wave profile.
TRIGGER POINTS / TENDINOPATHIES
SPINE TREATMENTS
Ro40 15 mm Energy beam transmitter with concave coupling surface, best for pain zones near the skin surface Penetration depth 0-35mm Intensity level: Medium
Double Tip shape to allows treatments of the paravertebral region
SPINE-ACTORS® 3 sizes span from 20 to 35mm
R15 15mm transmitter for any type of tendinopathies Penetration depth 0-35mm Intensity level: Medium
C15 CERAma-x® Ceramic Energy 15mm transmitter for any type of tendonopathies Penetration depth 0-35mm Intensity level: High DI15 Golden Depth 15mm Deep Impact®transmitter for deep target areas, chronic disorders, local trigger points Penetration depth 0-60mm Intensity level: High
FASCIA TREATMENTS
Unique shape especially designed to dissolve clots in the Fascia structures
PERI-ACTOR® KNUCKLE For Medium-sized and large fasciae thoracolombar fasciae, plantar fasciae, trigger bands, shoulder and neck region
A6 Acupuncture like transmitter 6mm for local trigger points Penetration depth 0-20mm Intensity level: Low
PERI-ACTOR SCOOP Treatment at or below the edges of bones: Front iliac crest, edge of the tibia
T10 Finger transmitter 10mm for deep target tendonopathies Penetration depth 0-40mm Intensity level: High
PERI-ACTOR® SCRAPER Treatment of all fasciae trigger band
F15 White soft transmitter 15mm for superficial pain regions, muscles
PERI-ACTOR SPHERE Punctual treatment of fasciae: Plantar fasciae, Arch of foot, Hand, Trigger points, Cervical spine Fasciae
of mastication, cervical spine Penetration depth 0-30mm Intensity level: Very Low
ATLAS Soft flexible tipped transmitter 15mm for highly sensitive regions and triggerpoints in the cervical spine Penetration depth 0-15mm Intensity level: Low
VIBRATION THERAPY
V10 10mm for superficlea trigger points
MYOFASCIAL TREATMENTS
D20-S Standard Oscillator, 20mm transmitter or muscle and connective tissue Penetration depth 0-50mm Intensity level: Medium D20-T Golden Oscillator 20mm transmitter for professional athletes, High energy application
V25 25mm for muscle massage
Penetration depth 0-50mm Intensity level: Very High
V40 40mm for large muscles groups
D35-S Large oscillator 35mm for large muscles and connective tissue Penetration depth 0-60mm Intensity level: Medium
FALCON®, V-ACTOR®, SPINE-ACTOR®, and PERI-ACTOR® are registered trademarks of Storz Medical AG
TECHNICAL INFORMATION 2174: 230V AC 50-60Hz 350VA 2173: 120V AC 50- 60Hz 350VA 2175: 100V AC 50-60Hz 400VA DIMENSIONS WxHxD: 410x1100x425mm WEIGHT: 30kg
COMPRESSED AIR OUTPUT: 0.3-5.0 bar POWER INCREMENT SETTINGS: 0.1 bar PULSE AMPLITUDE: Approx 2mm at 3 bar, idling (without coupling) PULSE WIDTH: Approx 6-12ms PULSE FREQUENCY: FALCON® handpiece 1-21Hz for RPW, V-ACTOR® handpiece 1-50Hz for vibration MODE: Single pulse or continuous USER INTERFACE: 7 inch, 800x480 pixels color graphic capacitive touch screen CONFORMITY: This device complies with the applicable standards EN/IEC 60601-1, CAN/CSA-C22.2 No.601.1, UL Std. No 60601-1. CLASSIFICATION ACCORDING TO MDD: class IIa device 93/42 60601-1 LEGAL MANUFACTURER: DJO France SAS - CE 2797
INTELECT ® RPW 2
ORDERING INFORMATION
PART NUMBER
DESCRIPTION
2174KIT
Intelect® RPW 2 230V unit set including standard accessories
2173KIT
Intelect® RPW 2 120V unit set including standard accessories
2175KIT
Intelect® RPW 2 100V unit set including standard accessories
STANDARD ACCESSORIES
PART NUMBER
DESCRIPTION
18080 FALCON® handpiece, including 2x projectile; 2x guiding tube; 1 cleaning brush, 1x wrench; 1x allen key 1x Power cord with EU plug for 2174KIT, 1x Power cord with North American plug for 2173KIT, 1x Power cord with Japanese plug for 2175KIT
Quick start guide booklets (available in multiple languages)
28178
Transmitter Ro40
13-28660*
29724
Transmitter D20-S black
22652
Transmitters tray
82-0274
Intelect RPW 2 pouch
22651
Gel bottle support cup
15-1140
USB Key
4248
1x Transmission gel, 250 ml
OPTIONAL ACCESSORIES
PART NUMBER
DESCRIPTION
18080
FALCON handpiece, including 2x projectile; 2x guiding tube; 1 cleaning brush, 1x wrench; 1x allen key
29104
Revision kit short including 2x projectiles; 2x guiding tubes short; 2x o-ring set; 1x o-ring guide
29801
A6 transmitter black
82-0274
Intelect RPW 2 pouch
29802
T10 transmitter black
22651
Gel bottle support cup
29729
C15 transmitter black
22652
Transmitter tray
29728
DI15 transmitter black
4248
24x Transmission gel, 250 ml
29726
F15 transmitter black
14820
Power cord EU
29724
D20-S transmitter black
14679
Power cord North America
29725
D35-S transmitter black
14821
Power cord JAPAN
28736
D20-T transmitter black
14814
Power cord Swiss
28178
Ro40 transmitter red
14819
Power cord Australia
18638
R15 transmitter black
14815
Power cord UK
29539
Atlas RPW transmitter
14816
Power cord India
V-ACTOR® HF handpiece set Including V-ACTOR®, V25 and V40 transmitters
14817
Power cord Israel
19365
14818
Power cord Denmark
29742
V-ACTOR V10 transmitter
28740
V-ACTOR V25 transmitter
28741
V-ACTOR V40 transmitter
Transmitter box including 9 transmitters (A6, T10, C15, DI15, F15, D20-S, D35-S, D20-T, Ro40) PERI-ACTOR® fascia transmitter set including 4 transmitters SPINE-ACTOR® transmitter set including 3 transmitters
31800
28945
28946
DJO® Global | 1 a Guildford Business Park | Guildford | Surrey | GU2 8XG | UNITED KINGDOM www.DJOglobal.eu
FALCON®, V-ACTOR®, SPINE-ACTOR®, and PERI-ACTOR® are registered trademarks of Storz Medical AG
“Individual results may vary. Neither DJO Global, Inc. nor any of its subsidiaries dispense medical advice. The contents of this document do not constitute medical, legal, or any other type of professional advice. Information related to various health, medical, and fitness conditions and their treatment is not meant to be a substitute for the advice provided by a physician or other medical professional.” Copyright © [2019] by DJO, LLC All rights reserved. No part of this publication may be reproduced, distributed, or transmitted in any form or by any means.
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8Made with FlippingBook - PDF hosting