GARN® GN1000 | Emissions Report

Report No. 102092693MID-008a Client: Dectra Corporation

Report Revised Date: March 31, 2016

Page 5 of 13

Model: WHS1000

II. SUMMARY OF TEST RESULTS II.A EPA Results

Table 1A. Data Summary Part A

W fuel

MC ave

Q in

Q out

Θ

Category

Load % Capacity

Target Load

Actual Load

Actual Load

Test Duration

Wood Weight as-fired

Wood Moisture

Heat Input

Heat Output

Btu/hr

Btu/hr

% of Max

hrs

lb

% DB 22.09

Btu

Btu

I

15% of Max 20% of Max

24,000

24,000

15%

22.9

106.98

765,110

548,404

II

32,000

32,000

20%

17.7

106.98

22.09

765,110

567,609

III

37.5% of max Max capacity

60,000

60,000

37.5%

9.9

106.98

22.09

765,110

596,871

IV

160,000

160,000

100%

3.9

106.98

22.09

765,110

619,691

Table 1B. Data Summary Part B E T E

η del

E

E g/hr

E g/kg

PM Output Based

PM Output Based

Delivered Efficiency HHV

Load % Capacity

Total PM Emissions

PM Factor

Category

PM Rate

lb/mmBtu Out

g

g/MJ

g/hr

g/kg

%

15% of Max 16-24% of Max 25-50% of max Max capacity

67.3

0.272

0.116

2.94

1.67

71.7%

I

67.3

0.263

0.112

3.79

1.67

74.2%

II

67.3

0.250

0.107

6.76

1.67

78.0%

III

67.3

0.241

0.103

17.37

1.67

81.0%

IV

Made with FlippingBook - professional solution for displaying marketing and sales documents online