Report No. 102092693MID-008a Client: Dectra Corporation
Report Revised Date: March 31, 2016
Page 5 of 13
Model: WHS1000
II. SUMMARY OF TEST RESULTS II.A EPA Results
Table 1A. Data Summary Part A
W fuel
MC ave
Q in
Q out
Θ
Category
Load % Capacity
Target Load
Actual Load
Actual Load
Test Duration
Wood Weight as-fired
Wood Moisture
Heat Input
Heat Output
Btu/hr
Btu/hr
% of Max
hrs
lb
% DB 22.09
Btu
Btu
I
15% of Max 20% of Max
24,000
24,000
15%
22.9
106.98
765,110
548,404
II
32,000
32,000
20%
17.7
106.98
22.09
765,110
567,609
III
37.5% of max Max capacity
60,000
60,000
37.5%
9.9
106.98
22.09
765,110
596,871
IV
160,000
160,000
100%
3.9
106.98
22.09
765,110
619,691
Table 1B. Data Summary Part B E T E
η del
E
E g/hr
E g/kg
PM Output Based
PM Output Based
Delivered Efficiency HHV
Load % Capacity
Total PM Emissions
PM Factor
Category
PM Rate
lb/mmBtu Out
g
g/MJ
g/hr
g/kg
%
15% of Max 16-24% of Max 25-50% of max Max capacity
67.3
0.272
0.116
2.94
1.67
71.7%
I
67.3
0.263
0.112
3.79
1.67
74.2%
II
67.3
0.250
0.107
6.76
1.67
78.0%
III
67.3
0.241
0.103
17.37
1.67
81.0%
IV
Made with FlippingBook - professional solution for displaying marketing and sales documents online