GARN® GN1000 | Emissions Report

Report No. 102092693MID-008a Client: Dectra Corporation

Report Revised Date: March 31, 2016

Page 6 of 13

Model: WHS1000

II.B Summary of other Data Table 2. Year Round Use Weighting

Weighting Factor

η del,i x F i - HHV

Category

E g/MJ,i x F i

E g/kg,i x F i

E lb/mmbtu,i x F i

E g/hr,i x F i

0.31 0.18 0.21 0.04 74%

0.051 0.027 0.029 0.005

0.73 0.40 0.46 0.08 1.67

0.12 0.06 0.07 0.01

0.08 0.05 0.05 0.01 0.19

0.437 0.238 0.275 0.050 1.000

I

II

III IV

0.11

0.262

Totals

II.C Summary of other Data

Run 2

Run 3

Run 4

Standby

Units

Steel Mass Water Mass

2200 8428

2200 8294

2200 8294

2200 lbs 8294 lbs

Fuel Load Weight Fuel MC (dry basis)

110.64

104.86

105.45

lbs

22.58

21.84

21.86

%

Kindling Mass

1.73 23.7

1.59 23.7

1.68 23.7

lbs

Kindling MC (dry basis)

%

Starting system temp. Ending System Temp. Average Room Temp.

126.92 203.58

121.91 196.58

117.75 188.73

172.50 F 168.20 F

67.55

64.76

57.20

66.80

Burn Time Burn Time

134.00

126 2.10

127 2.12

480.00 Minutes

2.23

8.00 Hours

Standby Test Duration

8 Hours

HHV

8600 41.59 18.62

8600 39.63 18.87

8600 39.88 18.84

BTU/lb

Dry Fuel Weight

Kg

Burn Rate

Kg/hr

Input

788,236 662,968 662,968

751,237 635,733 635,733

755,858 604,332 604,332

BTU BTU

Heat Stored

Average

Standby Loss Rate Total Emissions Total Emissions

44.2 BTU/hr-F

63.2

52.2

86.4

Grams

0.139

0.115

0.190

lbs

Category I Output Rate Category II Output Rate Category III Output Rate Category IV Output Rate

24000 32000 60000 160000

24000 32000 60000 160000

24000 32000 60000 160000

3756 BTU/hr 3756 BTU/hr 3756 BTU/hr 3756 BTU/hr