GARN® GN1000 | Emissions Report

Report No. 102092693MID-008a Client: Dectra Corporation

Report Revised Date: March 31, 2016

Page 7 of 13

Model: WHS1000

Average

Output Time Cat I Output Time Cat II Output Time Cat III Output Time Cat IV Category I Efficiency Category II Efficiency Category III Efficiency Category IV Efficiency

23.9 18.5 10.4

22.9 17.8 10.0

21.8 16.9

22.9 Hours 17.7 Hours 9.9 Hours 3.9 Hours

9.5 3.7

4.0

3.9

Average

72.7% 75.3% 79.2% 82.2%

73.2% 75.7% 79.6% 82.7%

69.1% 71.6% 75.2% 78.1%

71.7% 74.2% 78.0% 81.0%

lbm/mmBTU output lbm/mmBTU output lbm/mmBTU output lbm/mmBTU output

Category I Emissions

0.243

0.209

0.364

0.27

Category II Emissions

0.235

0.202

0.352

0.26

Category III Emissions

0.223

0.192

0.335

0.25

Category IV Emissions

0.215

0.185

0.323

0.24

III.

PROCESS DESCRIPTION

III.A. DISCUSSION RUN #1 (March 8, 2016). The starting temperature in the heat storage vessel was 126.9 o F. Burn time was 2.23 hours and ended with a heat storage vessel temperature of 202.5 o F. RUN #2 (March 10, 2016). The starting temperature in the heat storage vessel was 121.9 o F. Burn time was 2.10 hours and ended with a heat storage vessel temperature of 195.8 o F. RUN #3 (March 11, 2016). The starting temperature in the heat storage vessel was 120 o F. Burn time was 2.85 hours and ended with a heat storage vessel temperature of 170 o F. III.B. UNIT DIMENSIONS Overall dimensions are 67-in wide, 77-in deep, 65-in high.