1. Use the Scroll Left or Right key to toggle between Angle Threshold and Angle Polarity. 2. Use the Scroll Up or Down key to toggle through the degree values (0.25-5) for Angle Threshold. It move at increments of 0.25 3. Use the Scroll Up or Down key to toggle Angle Polarity options: Normal or Reverse 4. Press Enter key once setting is complete. 5. Press Main button to return to main display screen.
Angle Setup Angle Threshold: 2 deg Angle Polarity: Normal Angle Encoder: 360 Main
This allows an operator to set up an initial torque and follow up with a rotation to a specified angle and display the final torque. Torque + Angle
Selecting Torque + Angle
1. Press the "Menu" Button. 2. Use the Scroll Down key and select Setup by highlighting and pressing Enter . 3. Use the Scroll Up or Down key to toggle through the Setup options. 4. Press Enter key to select a setup setting for Torque +Angle .
Tolerance Auto Clear Angle Setup T+A Threshold First Peak Spindle Audit
Filter Units Mode Setup
Torque+Angle Thresh
1. Press the Right or Left key to toggle between the three settings: Angle, Torque Allow Ratchet 2. Use the Scroll Up or Down key to set Angle (increments of 0.25) 3. Use the Scroll Up or Down key to set Torque (increments of 0.5) 4. Use the Scroll Up or Down key to set “Yes” or “No” for allowing ratchet*. 5. Press Enter key once setting is complete. 6. Press Main button to return to main display screen. * Note - “Yes” allows for ratcheting the wrench back without accumulating angle.
Angle: Torque:
2.00
deg
50.000 lbf.in
Allow Ratchet: No Main