This feature is designed for auditing the operation of a Spindle Tool. An angle enabled transducer is required to oper- ate in this Mode. The unit checks the Torque and Angle setting of a Spindle. When the spindle stops, the LTT will dis- play and record the final angle, and final peak torque. Spindle Audit
Selecting Spindle Audit
1. Press the "Menu" Button. 2. Use the Scroll Down key and select Setup by highlighting and pressing Enter . 3. Use the Scroll Up or Down key to toggle through the Setup options. 4. Press Enter key to select a setup setting for Spindle Audit .
Tolerance Auto Clear Angle Setup T+A Threshold First Peak Spindle Audit
Filter Units Mode Setup
1. Press the Right or Left key to toggle between the settings. 2. Use the Scroll Up or Down key to set torque torque and angle settings. 4. Press Enter key once setting is complete. 5. Press Main button to return to main display screen.
Spindle Audit Thresh Initial Torque: 43 lbf.in
Low Angle: 25 deg High Angle: 28 deg
Main