Test

Fluke 771, 772 and 773 mA Process Clamp Meters

Recommended Accessories

Don’t break the loop on 4-20 mA signal measurements and save time with the Fluke 771, 772 and 773 Milliamp Process Clamp Meters. Three year warranty, (one year provided on mA clamp assembly and cable). Use the Fluke 772 and 773 to: • Source 4-20 mA signals for testing control system I/O or I/Ps • Simulate 4-20 mA signals for testing control system I/O • Measure 4-20 mA signals with in-circuit measurement • Power a transmitter with the 24 V loop power supply • Automatically ramp and step change the 4-20 mA output for remote testing Use the Fluke 773 to: • Measure DC voltage to verify 24 V power sup- plies or voltage I/O signals • Source DC voltage to test voltage input devices • Scaled mA output signal enables a logging DMM (289) to record 4-20 mA signal without breaking the loop • mA in/out: simultaneously source a mA signal while measuring a mA signal with the clamp

TL220

C550 Tool Bag

SureGrip™ Industrial

Test Lead Set See page 144

See page 153

Fluke 771, 772 and 773 mA Process Clamp Meters pay for themselves • The more you use them the more money you save • Measuring 4-20 mA signals (five) times without operator intervention can pay for the 771 • Saving a trip back to shop to get a loop calibrator can pay for the price difference of the 772 • Saving a trip back to the shop for a voltage test source can pay for the price difference of the 773

Fluke 773

Fluke 772

Fluke 771

Scaled mA

mA measure w/jaw

mA measure In circuit

Loop power 24 V

DCV source 0-10 V

DCV measure 0-30 V

mA source

mA sim

mA in/ out

output to mA input

● ● ●

771 772 773

— — — —

— —

— —

— —

— —

● ●

● ●

● ●

● ●

Resolution and range

Specifications Function

Accuracy

Notes

0 to 20.99 mA

0.2 % + 5 counts Measured by clamp

771, 772, 773

mA measurement

21.0 mA to 100.0 mA 1 % + 5 counts

Measured in series with test jacks Maximum mA drive: 24 mA into 1,000 ohms

772 and 773

mA measurement

0 to 24.00 mA

0.2 % + 2 counts

772 and 773

mA source

0 to 24.00 mA

0.2 % + 2 counts

772 and 773

mA simulate

0 to 24.00 mA

0.2 % + 2 counts Maximum voltage 50 V DC 0.2 % + 2 counts 2 mA maximum drive current

773

Voltage source

0 to 10.00 V DC

Included Accessories Fluke 771: Soft Carrying Case, User Manual. Fluke 772/773: Four AA Alkaline Batteries (installed), Soft Carrying Case, TL75 Test Leads, AC 72 Detachable Clip, TL940 Mini-hook Test Leads, Instruction Sheet, Hanging Tool with Hook and Loop Strap. Ordering Information

773

Voltage measure 0 to 30.00 V DC

0.2 % + 2 counts —

771

772

773

Battery

Two 1.5 V, Alkaline, IEC LR6

Four 1.5 V, Alkaline, IEC LR6

Working hours Size (HxWxL)

40 hours typical

12 hours @ 12 mA source into 500 ohms

59 mm x 38 mm x 212 mm

43.7 mm x 70 mm x 246.2 mm

Weight

260 g

410 g

Operating temperature

-10 °C to 50 ºC

IP rating

IP 40

FLUKE-771

Milliamp Process Clamp Meter Milliamp Process Clamp Meter Milliamp Process Clamp Meter

FLUKE-772

FLUKE-773

C ontact your local distributor for price and availability. www.fluke.com/au/wtb

www.fluke.com/au/PCT

Process Calibration Tools

105