Fluke 60 Series Infrared Thermometers
Recommended Accessories
Fluke 62 MAX, 62 MAX+ and 64 MAX IR Thermometers The Fluke 62 MAX, 62 MAX+ and new 64 MAX IR Thermometers have the precision you need to do your job accurately and will not break the budget. Designed and tested to survive a 3 metre drop, you can count on these lightweight, compact infrared thermometers to work when you need them to work–even in the harshest environments and when you’re not able to be there. • Precise laser technology for more accurate and repeatable measurements • Temperature accuracy of up to ≥ 0 °C: ± 1 °C or ± 1 % of reading whichever is greater with 20:1 distance to spot ratio (64 MAX) • Flashlight (64 MAX) and large, easy-to-read backlit LCD display for easy viewing even in dark environment • IP54 rated for extra protection against airborne contaminants • Get your tool to work when you can’t–set time and desired interval between measurements and Auto Capture will capture spot temperatures unattended (64 MAX) • 99 data point logging (64 MAX) • Displays the minimum, maximum or average temperature, or the difference between two measurements • Hi and Lo alarms for rapid display of measurements outside set limits • Dual rotating lasers to help you identify area to be measured (62 MAX+) • Small and lightweight, fits easily into your tool box • Three year warranty
FLK-TI-TRIPOD Tripod Mounting Accessory for 64 MAX See page 157
H6 Electrical Tester Holster See page 154
Recommended Kits Buy more, Save more
For more details see page 168 Fluke 116/62 MAX+ Technician’s Combo Kit For more details see page 169 Fluke T6-600/62 MAX+/1AC-II Infrared Thermometer and Electrical Tester Kit For more details see page 172 Fluke 417D/62MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit For more details see page 172 Fluke 62MAX+/323/1AC Combo Kit
Fluke 64 MAX
Fluke 62 MAX
Specifications
62 MAX
62 MAX+
64 MAX
Temperature range
-30 °C to 500 °C
-30 °C to 650 °C
- 30 °C to 600 °C
Accuracy
± 1.5 °C or ± 1.5 % of reading, whichever is greater -10 °C to 0 °C: ± 2.0 -30 °C to -10 °C: ±3.0
± 1.0 °C or ± 1.0 % of reading, whichever is greater -10 °C to 0 °C: ± 2.0 -30 °C to -10 °C: ± 3.0
± 1.0 °C or ± 1.0 % of reading, whichever is greater ± 2.0°C at -10 °C to 0 °C ± 3.0°C at -30 °C to -10 °C
Emissivity
0.10 to 1.00
Optical resolution
10:1 (calculated at 90 % energy)
12:1 (calculated at 90 % energy) EN/IEC 61010-1: 2001 FDA and EN 60825-1 Class II
20 : 1 (calculated at 90% energy)
Ordering Information Included Accessories Fluke 64 MAX, 62 MAX and 62 MAX+: Two AA Batteries and Instruction Sheet.
Compliance Laser safety
Single Laser IR Thermometer, 10:1 Spot Dual Laser IR Thermometer, 12:1 Spot IR Thermometer Clamp Meter and Voltage Detector Kit
FLUKE-62 MAX
FLUKE-62 MAX PLUS (+)
FLUKE 62 MAX+ /323/1AC
FLUKE-64 MAX
IR Thermometer
FLUKE-T6- 600/62MAX+ /1AC
2-in-1 ADV Elec Kit with 62MAX+ i400 AC Current Clamp T6-600 Tester, 62MAX+ & 1AC-II Combo Kit
1587KIT/62 MAX+
C ontact your local distributor for price and availability. www.fluke.com/au/wtb
www.fluke.com/au/thermometers
Infrared Thermometers
49
Made with FlippingBook Learn more on our blog