Fluke ii900 Sonic Leak Detection Industrial Imager
NEW
A fast, simple way to detect compressed air, steam, gas and vacuum leaks Equipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Sonic Industrial Imager enables maintenance teams to quickly and accurately locate air, gas and vacuum leaks in compressed air systems; even in noisy environments • 7” LCD Touchscreen • Frequency band of 2kHz to 52kHz (detected 150ml/ min leak at 7 bar for 10 mins) • SoundMap™ overlay for visual leak detection • Capture images in JPEG or PNG format with user input notes function
Recommended Accessories
BP291 4500 mAh capacity
EBC290 External
Li-ion Battery See page 159
Battery Charger See page 162
Fluke ii900
• Capture videos in MP4 format • Manual frequency filtering • Two year warranty
CXT1000 Hard Carry Case See page 153
FLK-TIX5XX-NECK Neck Strap
New SoundSight™ Technology Specifically designed for noisy production facilities the new SoundSight™ technology is simple to learn and easy to implement. The 7” LCD touchscreen overlays a SoundMap™ on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant – during peak operations. For the first time, you can quickly and easily identify the air leak repairs needed to ensure efficient operations and reduce utility bills. Images can be saved and exported for reporting purposes. Never leave air leaks unattended again. With minimal training, the ii900 enables you to: • Fast, simple leak location identification • Optimise air compressors—delay the capital expense of installing additional compressors • Ensure proper air pressure to pneumatic equipment
Fluke ii900 Application
• Lower energy and gas costs • Reduce leak detection time • Improve reliability of the production line • Make leak detection part of the typical maintenance routine • Train the team in a matter of minutes • Validate repairs on the spot Find out more > www.fluke.co/ii900anz
ii900
Key Features
Sensor # of Microphones Frequency Band
64 digital MEMS microphones
2 kHz to 52 kHz
Sound Pressure Sensitivity Operational Distance Range
150 ml/min leak at 7 bar from 10 metres
0.5 to 50 metres
Built-in Digital Camera (visible light) Field of view
65 ° ± 3 ° Fixed lens
Focus
Acoustic Measurements
29.7 dB to 120 dB SPL at 2kHz 16 dB to 106.3 dB SPL (± 1 dB) at 19 kHz 21.4 dB to 117 dB SPL (± 1 dB) at 52 kHz
Measurement Range
General Specifications Battery Life
≥2 hours (product includes spare battery)
Main Unit Rating Sensor Head Rating
IP40 protection against particles 1mm or greater and dripping water
IP51
Included Accessories AC Power Supply, Battery Pack Charger, Two Rugged Lithium Ion Smart Battery Packs, USB Cable, Rugged, Hard Carrying Case, Two Rubber Array Covers, Adjustable Hand Strap and Neck Strap.
Ordering Information
Fluke-II900 Sonic Industrial Imager
C ontact your local distributor for price and availability. www.fluke.com/au/wtb