Test

Fluke ii900 Sonic Leak Detection Industrial Imager

NEW

A fast, simple way to detect compressed air, steam, gas and vacuum leaks Equipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Sonic Industrial Imager enables maintenance teams to quickly and accurately locate air, gas and vacuum leaks in compressed air systems; even in noisy environments • 7” LCD Touchscreen • Frequency band of 2kHz to 52kHz (detected 150ml/ min leak at 7 bar for 10 mins) • SoundMap™ overlay for visual leak detection • Capture images in JPEG or PNG format with user input notes function

Recommended Accessories

BP291 4500 mAh capacity

EBC290 External

Li-ion Battery See page 159

Battery Charger See page 162

Fluke ii900

• Capture videos in MP4 format • Manual frequency filtering • Two year warranty

CXT1000 Hard Carry Case See page 153

FLK-TIX5XX-NECK Neck Strap

New SoundSight™ Technology Specifically designed for noisy production facilities the new SoundSight™ technology is simple to learn and easy to implement. The 7” LCD touchscreen overlays a SoundMap™ on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant – during peak operations. For the first time, you can quickly and easily identify the air leak repairs needed to ensure efficient operations and reduce utility bills. Images can be saved and exported for reporting purposes. Never leave air leaks unattended again. With minimal training, the ii900 enables you to: • Fast, simple leak location identification • Optimise air compressors—delay the capital expense of installing additional compressors • Ensure proper air pressure to pneumatic equipment

Fluke ii900 Application

• Lower energy and gas costs • Reduce leak detection time • Improve reliability of the production line • Make leak detection part of the typical maintenance routine • Train the team in a matter of minutes • Validate repairs on the spot Find out more > www.fluke.co/ii900anz

ii900

Key Features

Sensor # of Microphones Frequency Band

64 digital MEMS microphones

2 kHz to 52 kHz

Sound Pressure Sensitivity Operational Distance Range

150 ml/min leak at 7 bar from 10 metres

0.5 to 50 metres

Built-in Digital Camera (visible light) Field of view

65 ° ± 3 ° Fixed lens

Focus

Acoustic Measurements

29.7 dB to 120 dB SPL at 2kHz 16 dB to 106.3 dB SPL (± 1 dB) at 19 kHz 21.4 dB to 117 dB SPL (± 1 dB) at 52 kHz

Measurement Range

General Specifications Battery Life

≥2 hours (product includes spare battery)

Main Unit Rating Sensor Head Rating

IP40 protection against particles 1mm or greater and dripping water

IP51

Included Accessories AC Power Supply, Battery Pack Charger, Two Rugged Lithium Ion Smart Battery Packs, USB Cable, Rugged, Hard Carrying Case, Two Rubber Array Covers, Adjustable Hand Strap and Neck Strap.

Ordering Information

Fluke-II900 Sonic Industrial Imager

C ontact your local distributor for price and availability. www.fluke.com/au/wtb