FC1700/FC1900/SF3100/SF4200: EPA 2016 Certification Report

VERSION: 2.2

12/14/2009

Manufacturer: HY-C

Appliance Type: Non-Cat (Cat, Non-Cat, Pellet)

Model: FC1700 Date: 5/10/2016

Temp. Units Weight Units

Default Fuel Values

F (F or C) lb (kg or lb)

Run: 2

D. Fir

Oak

Control #: G102523311

HHV (kJ/kg)

19,810 19,887

Test Duration: 405

%C %H %O

48.73

50 6.6

Output Category: 2

Fuel Data

6.87 43.9

D. Fir

42.9

Wood Moisture (% wet): Load Weight (lb wet): Burn Rate (dry kg/h): Total Particulate Emissions:

HHV 19,887 kJ/kg

%Ash

18.59 43.81

0.5

0.5

%C %H %O

50 6.6

2.40

Note 1: For other fuels, use the heating value and fuel composition determined by analysis of fuel sample in accordance with Clause 9.2.

26.23 g

42.9

%Ash

0.5

Averages

0.43

7.32

12.73 372.44 68.43

Temp. (ºF)

Note 2: In cases where the "Fuel Weight Remaining" is the same for three or more readings in a row, a "divide by zero error" will occur in the calculation sheet. In such cases, adjust the weight values by interpolation between the first occurence and the next reading showing a decrease in weight.

Elapsed

Fuel Weight Remaining (lb)

Flue Gas Composition (%)

Flue Room Gas Temp

O 2

Time (min)

CO CO 2

0 1 2 3 4 5 6 7 8 9

43.81 43.51 43.01 42.69 42.42 42.20 41.93 41.72 41.51 41.22 41.01 40.72 40.48 40.12 39.90 39.61 39.30 39.01 38.71

0.56 0.32 0.65 0.56 0.39 0.32 0.39 0.44 0.49 0.54 0.56 0.58 0.59 0.60 0.61 0.62 0.59 0.54 0.48

3.55 16.47 391.4 68.8 2.13 18.14 658.6 68.7 3.99 15.63 844.8 69.3 8.69 10.51 651.7 69.2 9.55 10.62 523.2 69.0 7.62 12.69 509.0 69.3 7.09 13.21 502.4 69.7 7.04 13.25 505.8 69.2 8.53 556.7 69.7 7.11 13.17 508.3 69.0 7.27 13.02 508.9 69.2 7.29 12.98 509.1 69.6 7.36 12.92 509.5 69.1 7.48 12.80 510.0 69.3 7.58 12.69 516.8 69.0 7.70 12.58 528.6 69.2 7.95 12.35 546.8 69.2 8.37 11.92 561.9 68.8 8.91 11.42 574.5 69.4

10.99

10 11 12 13 14 15 16 17 18

Made with FlippingBook - professional solution for displaying marketing and sales documents online