Intertek Testing Services
REPORT DATA
SFBA EPA ADJUSTED EMISSION RESULTS
Client: HY-C
Manufacturer: HY-C
RESULTS
Run: 2
Model:FC1700
Date: 5/10/16
Date:5/10/16
Average emission rate:(gr/hr)
3.9
Project: G102523311
Run:2
Model: FC1700
Project #: G102523311
Burn Rate (Dry kg/hr):
2.412 Fuel Moisture (Dry):
22.84
Test Duration: 405
Stack Static (neg):
0.250
(minutes)
Barometer:
28.895 68.43
Average Room Temp:
BAROMETRIC PRESSURE
Average:
28.895 28.87 28.92
Start: End:
DRY GAS METER VALUES
Burn Rate:
2.412
VOLUMES SAMPLED
DGM #1 Final:
48.391 0.000 48.372 0.000
DGM #1: DGM #2:
47.67437 47.78218
Initial:
DGM #2 Final:
TOTAL TUNNEL VOLUME (scf):
243115
Initial:
Filter 1: Filter 2:
72.39 73.13 78.24 71.67 71.81
SAMPLE RATIOS
TEMPERATURES (DEG. RANKIN)
Tunnel:
Sample Train 1: Sample Train 2:
5099.486 5087.981
DGM #1: DGM #2:
531.675 531.811
DGM 1: DGM 2:
Water Collected:
TOTAL EMISSIONS
CALIBRATION FACTORS
26.01 26.46
Sample Train 1 (g): Sample Train 2 (g):
DGM #1: DGM #2:
0.9852 0.9878
Room Temp
Bar Pressure
Relative Humidity Air Velocity
Before After
Before 28.87
After 28.92
Before After
Before After
69
0
47
42
0
0
EMISSION RATES
TUNNEL FLOW RATE:
600.284
3.85 3.92
Pre-Test Load
Sample Train 1 (g/hr): Sample Train 2 (g/hr):
Test Load
PARTICULATE CATCH (mg)
weight (wet lb)
Moisture Coal Bed Weight
Loading Density 11.023
Moisture Piece Number of
(Dry %) #DIV/0!
Weight
(wet lb)
(Dry %)
Length 2x4 4x4
Total Sample Train 1: Total Sample Train 2:
5.1 5.2
0.00
0.0
44.09
22.84 20.00
Filter and seal Sample Train 1:
4
4.7 Average Dilution Tunnel Measurements
Sample Data
MAX Allowed
7.50% Filter and seal Sample Train 2:
Probe Sample Train 1: Probe Sample Train 2:
Burn
Velocity Flow Rate Temp Total Sample
Particulate Catch
1.1
DEVIATION:
1.72%
0.5 Time (Ft/sec) (dscf/min)
(R)
1
2
1
2
405
13.79 600.28 540.76 Dilution Tunnel Dual Train Precision
47.67
47.78
5.1
5.2
Train 1
Train 2
Room Particulate Correction
Sample Ratios
Total Emissions (g)
Cs Cr
0.000106976 0.000108827
Mr
0 Milligram Catch (mg)
0
0
Vmr
Train 1 Train 2 Train 1 Train 2 Deviation (%)
52.3422 Total Volume Sampled (dscf)
Et
26.01
26.46
5099.49 5087.98 26.01
26.46
1.72%
Rotometer (glass) at 100 flow rate is 0.12924 cfm
Change Surface
Et
AVERAGE
26.23 Grams Emissions
Burn Average Temp
Initial Draft 0.041
Run AverageComb 62.852 68.15
Rate Catalyst
Surface Temp
Time Draft Chamber 405 0.031 #REF!
2.412
#REF!
0.00
0.00
Run
Date Burn Rate Emission
2
5/10/2016 2.412
3.886
Made with FlippingBook - professional solution for displaying marketing and sales documents online