FC1700/FC1900/SF3100/SF4200: EPA 2016 Certification Report

VERSION: 2.2

12/14/2009

Manufacturer: HY-C

Appliance Type: Non-Cat (Cat, Non-Cat, Pellet)

Model: FC1700 Date: 5/11/2016

Temp. Units Weight Units

Default Fuel Values

F (F or C) lb (kg or lb)

Run: 3

D. Fir

Oak

Control #: G102523311

HHV (kJ/kg)

19,810 19,887

Test Duration: 150

%C %H %O

48.73

50 6.6

Output Category: 4

Fuel Data

6.87 43.9

D. Fir

42.9

Wood Moisture (% wet): Load Weight (lb wet): Burn Rate (dry kg/h): Total Particulate Emissions:

HHV 19,887 kJ/kg

%Ash

18.68 37.81

0.5

0.5

%C %H %O

50 6.6

5.58

Note 1: For other fuels, use the heating value and fuel composition determined by analysis of fuel sample in accordance with Clause 9.2.

19.91 g

42.9

%Ash

0.5

Averages

0.48

10.83

9.17 639.75 71.70

Temp. (ºF)

Note 2: In cases where the "Fuel Weight Remaining" is the same for three or more readings in a row, a "divide by zero error" will occur in the calculation sheet. In such cases, adjust the weight values by interpolation between the first occurence and the next reading showing a decrease in weight.

Elapsed

Fuel Weight Remaining (lb)

Flue Gas Composition (%)

Flue Room Gas Temp

O 2

Time (min)

CO CO 2

0 1 2 3 4 5 6 7 8 9

37.81 37.22 36.62 36.10 35.21 34.73 34.23 33.73 33.22 32.72 32.33 31.82 31.42 30.92 30.42 29.92 29.52 29.02 28.52

0.21 0.21 0.21 0.21 0.32 0.03 1.35 1.89 1.46 1.11 0.93 0.83 0.78 0.78 0.79 0.74 0.75 0.80 0.85

2.10 19.33 619.1 71.1 2.10 19.34 850.0 70.5 2.10 19.35 983.4 71.4 2.10 19.35 1080.2 71.4 1.95 18.84 824.4 71.0 0.34 20.45 790.7 71.1 8.70 10.68 785.1 70.6

15.56 16.13 16.22 16.22 16.21 16.20 16.28 16.33 16.36 16.45 16.47 16.48

3.79 781.8 70.9 3.52 777.6 71.4 3.64 773.2 71.1 3.75 773.5 71.4 3.85 772.9 71.2 3.90 773.1 71.0 3.84 773.0 71.2 3.78 777.0 72.0 3.79 778.3 70.8 3.73 778.5 71.8 3.68 781.2 71.7 3.67 781.9 71.0

10 11 12 13 14 15 16 17 18

Made with FlippingBook - professional solution for displaying marketing and sales documents online