FC1700/FC1900/SF3100/SF4200: EPA 2016 Certification Report

VERSION: 2.2

12/14/2009

Manufacturer: HY-C

Appliance Type: Non-Cat (Cat, Non-Cat, Pellet)

Model: FC1700 Date: 5/9/2016

Temp. Units Weight Units

Default Fuel Values

F (F or C) lb (kg or lb)

Run: 1

D. Fir

Oak

Control #: G102523311

HHV (kJ/kg)

19,810 19,887

Test Duration: 214

%C %H %O

48.73

50

Output Category: 3

Fuel Data

6.87 43.9

6.6

D. Fir

42.9

Wood Moisture (% wet): Load Weight (lb wet): Burn Rate (dry kg/h): Total Particulate Emissions:

HHV 19,887 kJ/kg

%Ash

0.5

0.5

18.37 36.74

%C %H %O

50

3.81

6.6

Note 1: For other fuels, use the heating value and fuel composition determined by analysis of fuel sample in accordance with Clause 9.2.

19.57 g

42.9

%Ash

0.5

10.88 502.57 74.81

Averages

0.42

9.10

Temp. (ºF)

Note 2: In cases where the "Fuel Weight Remaining" is the same for three or more readings in a row, a "divide by zero error" will occur in the calculation sheet. In such cases, adjust the weight values by interpolation between the first occurence and the next reading showing a decrease in weight.

Elapsed

Fuel Weight Remaining (lb)

Flue Gas Composition (%)

Flue Room Gas Temp

O 2

Time (min)

CO CO 2

0 1 2 3 4 5 6 7 8 9

36.74 36.24 35.54 34.84 34.35 33.84 33.43 32.95 32.54 32.05 31.64 31.24 30.83 30.53 30.15 29.74 29.33 28.94 28.63

0.12 0.09 0.25 0.90 1.62 2.43 1.80 1.29 0.99 0.80 0.65 0.59 0.56 0.49 0.39 0.30 0.22 0.20 0.18

11.03

8.91 761.2 75.5

6.27 14.02 961.4 75.8

10.79 15.29 16.47 17.29 17.19 16.82 16.40 16.15 15.95 15.69 15.49 15.14 14.81 14.56 14.56 14.50 14.31

8.59 1065.9 75.4 3.45 833.0 76.7 2.20 794.5 76.1 2.14 784.7 75.3 2.61 773.5 75.3 3.10 763.4 76.1 3.65 754.4 75.6 4.04 746.9 75.9 4.35 743.2 75.5 4.64 737.0 75.9 4.86 727.7 75.0 5.25 720.6 75.7 5.60 716.3 76.1 5.89 713.6 75.6 5.93 709.6 75.7 5.99 707.1 75.5 6.19 701.1 75.3

10 11 12 13 14 15 16 17 18

Made with FlippingBook - professional solution for displaying marketing and sales documents online