REPORT DATA
SFBA EPA ADJUSTED EMISSION RESULTS
Client: HY-C
Manufacturer: HY-C
RESULTS
Run: 3
Model:FC1700
Date: 5/11/16
Date:5/11/16
Average emission rate:(gr/hr)
7.5
Project: G102523311
Run:3
Model: FC1700
Project #: G102523311
Burn Rate (Dry kg/hr):
5.629
Fuel Moisture (Dry): Stack Static (neg):
22.96
Test Duration: 150
0.266
(minutes)
Barometer:
29.03 71.70
Average Room Temp:
BAROMETRIC PRESSURE
Average:
29.03 29.03 29.03
Start: End:
DRY GAS METER VALUES
Burn Rate:
5.629
VOLUMES SAMPLED
DGM #1 Final:
17.622 0.000 17.608 0.000
DGM #1: DGM #2:
17.36123 17.39295
Initial:
DGM #2 Final:
TOTAL TUNNEL VOLUME (scf):
89856
Initial:
Filter 1: Filter 2:
79.97 80.62 99.94 73.32 73.07
SAMPLE RATIOS
TEMPERATURES (DEG. RANKIN)
Tunnel:
Sample Train 1: Sample Train 2:
5175.699 5166.260
DGM #1: DGM #2:
533.322 533.067
DGM 1: DGM 2:
Water Collected:
TOTAL EMISSIONS
CALIBRATION FACTORS
17.08 20.67
Sample Train 1 (g): Sample Train 2 (g):
DGM #1: DGM #2:
0.9852 0.9878
Room Temp
Bar Pressure
Relative Humidity Air Velocity
Before After
Before 29.03
After 29.03
Before After
Before After
71
0
46
43
0
0
EMISSION RATES
TUNNEL FLOW RATE:
599.043
6.83 8.27
Sample Train 1 (g/hr): Sample Train 2 (g/hr):
Test Load
Pre-Test Load
PARTICULATE CATCH (mg)
weight (wet lb)
Moisture Coal Bed Weight
Loading Density
Moisture Piece Number of
Total Sample Train 1: Total Sample Train 2:
(Dry %) #DIV/0!
Weight
(wet lb)
(Dry %)
Length 2x4 4x4
3.3
0.00
0.0
38.15
9.538
22.96 20.00
4
Filter and seal Sample Train 1:
3.3
MAX Allowed
7.50% Filter and seal Sample Train 2:
4 Average Dilution Tunnel Measurements
Sample Data
Probe Sample Train 1: Probe Sample Train 2:
Burn
Velocity Flow Rate Temp Total Sample
Particulate Catch
0
DEVIATION:
19.00%
0 Time (Ft/sec) (dscf/min)
(R)
1
2
1
2
150
13.06 599.04 515.68 Dilution Tunnel Dual Train Precision
17.36
17.39
3.3
4.0
Train 1
Train 2
Room Particulate Correction
Cs Cr
0.000190079 0.000229978
Mr
Sample Ratios
Total Emissions (g)
0 Milligram Catch (mg)
0
0
Vmr
Train 1 Train 2 Train 1 Train 2 Deviation (%)
19.386 Total Volume Sampled (dscf)
Et
17.08
20.67
5175.70 5166.26 17.08
20.67
19.00%
Rotometer (glass) at 100 flow rate is 0.12924 cfm
Change Surface
Et
AVERAGE
18.87 Grams Emissions
Burn Average Temp
Initial Draft 0.049
Run AverageComb 62.85268.1502
Rate Catalyst
Surface Temp
Time Draft Chamber 150 0.045 #REF!
1.214 1.468 0.255
5.629
#REF!
0.00
0.00
Run
Date Burn Rate Emission
3
5/11/2016 5.629
7.549
Made with FlippingBook - professional solution for displaying marketing and sales documents online