FC1700/FC1900/SF3100/SF4200: EPA 2016 Certification Report

VERSION: 2.2

12/14/2009

Manufacturer: HY-C

Appliance Type: Non-Cat (Cat, Non-Cat, Pellet)

Model: FC1700 Date: 5/11/2016

Temp. Units Weight Units

Default Fuel Values

F (F or C) lb (kg or lb)

Run: 4

D. Fir

Oak

Control #: G102523311

HHV (kJ/kg)

19,810 19,887

Test Duration: 154

%C %H %O

48.73

50 6.6

Output Category: 4

Fuel Data

6.87 43.9

D. Fir

42.9

Wood Moisture (% wet): Load Weight (lb wet): Burn Rate (dry kg/h): Total Particulate Emissions:

HHV 19,887 kJ/kg

%Ash

18.82 40.53

0.5

0.5

%C %H %O

50 6.6

5.82

Note 1: For other fuels, use the heating value and fuel composition determined by analysis of fuel sample in accordance with Clause 9.2.

22.92 g

42.9

%Ash

0.5

Averages

0.38

9.17

10.84 670.72 77.70

Temp. (ºF)

Note 2: In cases where the "Fuel Weight Remaining" is the same for three or more readings in a row, a "divide by zero error" will occur in the calculation sheet. In such cases, adjust the weight values by interpolation between the first occurence and the next reading showing a decrease in weight.

Elapsed

Fuel Weight Remaining (lb)

Flue Gas Composition (%)

Flue Room Gas Temp

O 2

Time (min)

CO CO 2

0 1 2 3 4 5 6 7 8 9

40.53 39.82 39.02 38.23 37.43 36.63 35.93 35.34 34.74 34.24 33.74 33.13 32.73 32.23 31.74 31.23 30.83 30.33 29.93

0.44 0.26 0.87 2.04 1.97 1.91 1.81 1.95 2.83 2.18 1.77 1.50 1.21 0.96 0.83 0.69 0.59 0.55 0.53

12.75

7.03 839.1 78.5

9.60 10.57 995.9 79.2

9.82 13.65 14.24 14.34 14.21 14.41 14.78 14.67 14.60 14.55 14.35 14.17 13.94 13.59 13.08 12.63 12.40

9.79 1081.6 79.0 5.13 1108.2 78.8 4.70 1140.4 79.6 4.82 1153.2 79.8 5.15 888.7 79.6 5.14 849.2 80.1 5.00 837.2 80.1 5.25 827.2 80.3 5.41 823.6 79.3 5.53 820.6 79.3 5.80 818.0 79.3 6.01 814.3 79.9 6.27 810.2 79.8 6.69 806.3 80.3 7.25 801.0 78.0 7.72 799.3 78.1 7.95 798.6 77.6

10 11 12 13 14 15 16 17 18

Made with FlippingBook - professional solution for displaying marketing and sales documents online