FC1700/FC1900/SF3100/SF4200: EPA 2016 Certification Report

Intertek Testing Services

REPORT DATA

SFBA EPA ADJUSTED EMISSION RESULTS

Client: HY-C

Manufacturer: HY-C

RESULTS

Run: 6

Model:FC1700

Date: 6/22/16

Date:6/22/16

Average emission rate:(gr/hr)

15.8

Project: G102523311

Run:6

Model: FC1700

Project #: G102523311

Burn Rate (Dry kg/hr):

2.594

Fuel Moisture (Dry): Stack Static (neg):

26.62

Test Duration: 366

0.449

(minutes)

Barometer:

28.87 77.50

Average Room Temp:

BAROMETRIC PRESSURE

Average:

28.87 28.89 28.85

Start: End:

DRY GAS METER VALUES

Burn Rate:

2.594

VOLUMES SAMPLED

DGM #1 Final:

47.752 0.000 47.750 0.000

DGM #1: DGM #2:

47.04510 47.16776

Initial:

DGM #2 Final:

TOTAL TUNNEL VOLUME (scf):

272680

Initial:

Filter 1: Filter 2:

77.56 77.80 88.92 75.88 76.21

SAMPLE RATIOS

TEMPERATURES (DEG. RANKIN)

Tunnel:

Sample Train 1: Sample Train 2:

5796.130 5781.058

DGM #1: DGM #2:

535.880 536.207

DGM 1: DGM 2:

Water Collected:

TOTAL EMISSIONS

CALIBRATION FACTORS

99.11 93.08

Sample Train 1 (g): Sample Train 2 (g):

DGM #1: DGM #2:

0.9852 0.9878

Room Temp

Bar Pressure

Relative Humidity Air Velocity

Before After

Before 28.89

After 28.85

Before After

Before After

78

0

41

42

0

0

EMISSION RATES

TUNNEL FLOW RATE:

745.026

16.25 15.26

Sample Train 1 (g/hr): Sample Train 2 (g/hr):

Test Load

Pre-Test Load

PARTICULATE CATCH (mg)

weight (wet lb)

Moisture Coal Bed Weight

Loading Density 11.043

Moisture Piece Number of

Total Sample Train 1: Total Sample Train 2:

(Dry %) #DIV/0!

Weight

(wet lb)

(Dry %)

Length 2x4 4x4

17.1 16.1

0.00

0.0

44.17

26.62 20.00

Filter and seal Sample Train 1:

15.8

MAX Allowed

7.50% Filter and seal Sample Train 2:

15.5 Average Dilution Tunnel Measurements

Sample Data

Probe Sample Train 1: Probe Sample Train 2:

Burn

Velocity Flow Rate Temp Total Sample

Particulate Catch

1.3

DEVIATION:

6.28%

0.6 Time (Ft/sec) (dscf/min)

(R)

1

2

1

2

366

17.45 745.03 550.93 Dilution Tunnel Dual Train Precision

47.05

47.17 17.1 16.1

Train 1

Train 2

Room Particulate Correction

Cs Cr

0.000363481 0.000341335

Mr

Sample Ratios

Total Emissions (g)

0 Milligram Catch (mg)

0

0

Vmr

Train 1 Train 2 Train 1 Train 2 Deviation (%)

47.30184 Total Volume Sampled (dscf)

Et

99.11

93.08

5796.13 5781.06 99.11

93.08

6.28%

Rotometer (glass) at 100 flow rate is 0.12924 cfm

Change Surface

Et

AVERAGE

96.09 Grams Emissions

Burn Average Temp

Initial Draft 0.029

Run AverageComb 62.85268.1502

Rate Catalyst

Surface Temp

Time Draft Chamber 366 0.026 #REF!

System 1 System 2 Deviation

6.264 g/kg 5.882 g/kg -0.382 g/kg

2.594

#REF!

0.00

0.00

Run

Date Burn Rate Emission 6/22/2016 2.594 15.753

6

Made with FlippingBook - professional solution for displaying marketing and sales documents online