Project No: G102523311
Manufacturer: HY-C
Model: FC1700
Date:
11/11/2016
Tech: BZ
Weighted Average for Solid Fuel Aired Heating Appliances
CAT Load % Capacity
Tgt Load (Btu/hr)
Act Load (Btu/hr)
Test Duration (Hours)
WoodWt
Q in
Q out
h N
E T
E E Output
E Input
E
(Lb)
(Btu)
(Btu)
(%)
(g)
(g/MJ) (lb/mmbtu) (lb/mmbtu) (g/hr)
<35% of max
I
26,250 25,586
6.90
43.24
297,589
176,540
59.3%
20.26
0.11
0.25
0.15
2.94
35-53% of max 53-76% of max
II
33,000 29,088
6.75
44.09
305,086
196,343
64.4%
26.23
0.13
0.29
0.19
3.89
III
48,750 51,504
3.57
37.51
260,270
183,699
70.6%
19.29
0.10
0.23
0.16
5.41
Max capacity 75,000 67,337
IV
2.53
39.67
273,941
170,695
62.3%
20.50
0.11
0.26
0.16
8.09
Efficiency Efficiency
#DIV/0!
#DIV/0!
Average BTU/hr for 8 hr burn time
#DIV/0!
Y1 Y2 X1 X2 Z1 Z2 Z3 Z4
Test duration above 8 hours Test duration just below 8 hours Actual load (BTU/hr) for duration Y1 Actual load (BTU/hr) for duration Y2 Efficiency for duration Y1 HHV Efficiency for duration Y2 HHV Efficiency for duration Y1 LHV Efficiency for duration Y2 LHV
HHV
LHV
If the test is ASTM put a 0, if EPA put a 1
0
Maximum output rating BTU/hr:
75,000
Year Round Use Weighting
Weighting
Input
Output
x F i
E g/MJ,I x F i E lb/mmbtu x FE lb/mmbtu x F i E g/hr x F i
CO g/hr x F i
Category Factor
I
0.250 0.250 0.250 0.250 1.000
0.148 0.161 0.176 0.156 0.641
0.027 0.032 0.025 0.028 0.112
0.038 0.047 0.041 0.041 0.167
0.063 0.074 0.058 0.066 0.261
0.734 0.972 1.352 2.021 5.079
38.365 30.845 39.383 30.845 139.438
II
III IV
Totals
C:\Users\PVanderEems\Desktop\EPA Certification_FC1700_FC1900_SF3100_SF4200\Appendix B - Data and Calculation Forms\[Weighted Avg.xls]Sheet1 Remember to use Paste special when copying to this area, values only!
Category 1 test results Paste in F51
Category 2 test results paste in L51
Category
1 7
Category
2 2
Run Number
Run Number
Weighted Avg
Made with FlippingBook - professional solution for displaying marketing and sales documents online