Certificate Number A2157371
Certificate of Calibration
Page 2 of 2
04/26/16 Issue Date:
Data Sheet
Parameter
Nominal
Minimum
Maximum As Found
As Left
Uncertainty
Unit ADJ/FAIL
100.0
98.0
102.0
101.0
101.0
27.0027 Grams
lbs
Weight Accuracy
200.0
198.0
202.0
201.0
201.0
27.0027 Grams
lbs
Weight Accuracy
300.0
298.0
302.0
302.0
302.0
27.0027 Grams
lbs
Weight Accuracy
400.0
398.0
402.0
402.0
402.0
27.0027 Grams
lbs
Weight Accuracy
500.0
498.0
502.0
502.0
502.0
27.0027 Grams
lbs
Weight Accuracy
1000.0
998.0
1002.0
1000.0
1000.0
27.0027 Grams
lbs
Weight Accuracy
100.0
98.0
102.0
101.0
101.0
27.0027 Grams
lbs
Shift Test RF
100.0
98.0
102.0
101.0
101.0
27.0027 Grams
lbs
Shift Test LF
100.0
98.0
102.0
101.0
101.0
27.0027 Grams
lbs
Shift Test RR
100.0
98.0
102.0
101.0
101.0
27.0027 Grams
lbs
Shift Test LR
100.0
98.0
102.0
101.0
101.0
27.0027 Grams
lbs
Shift Test Center
TM
I Technical Maintenance, Inc.
3248 FOREST VIEW ROAD, ROCKFORD, IL 61109 Phone: 779-774-3877 Fax 779-774-3884
ISO/IEC 17025:2005
Rev. 14 3/14/16
www.tmicalibration.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online