FC1500/SF2600: EPA 2016 Certification Report

HY-C Company, LLC

Date: November 10, 2016

Project No. G102527563

Page 15 of 15

VI.B.(2).

TUNNEL VELOCITY/FLOW MEASUREMENT

The tunnel velocity is calculated from a center point Pitot tube signal multiplied by an adjustment factor. This factor is determined by a traverse of the tunnel as prescribed in EPA Method 1. Final tunnel velocities and flow rates are calculated from EPA Method 2, Equation 6.9 and 6.10. (Tunnel cross sectional area is the average from both lines of traverse.) Pitot tubes are cleaned before each test and leak checks are conducted after each test.

VI.B.(3). PM SAMPLING PROPORTIONALITY

Proportionality was calculated in accordance with ASTM E2515-11. The data and results are included in Appendix C.

VII. CONCLUSION

This test demonstrates that this unit is an affected facility under the definition given in the regulation. The emission rate of 0.368 g/hr meets the EPA requirements for the Step 1 limits. Model FC1500 was tested as a representative sample of similar model SF2600. SF2600 is identical to the FC1500, with the only difference being the color. SF Series is sold under the Shelter Furnace name and the FC Series is sold under the Fire Chief Industries name. INTERTEK TESTING SERVICES NA

Evaluated by:

Ken Slater Associate Engineer - Hearth

Reviewed by:

Brian Ziegler Technical Team Lead - Hearth

Made with FlippingBook - professional solution for displaying marketing and sales documents online