FC1500/SF2600: EPA 2016 Certification Report

Project No: G102527563

Manufacturer: HY-C

Model: FC1500

Date:

6/13/2016

Tech: BZ

Weighted Average for Solid Fuel Aired Heating Appliances

CAT Load % Capacity

Tgt Load (Btu/hr)

Act Load (Btu/hr)

Test Duration (Hours)

WoodWt

Q in

Q out

h N

E T

E

E Output

E Input

E

(Lb)

(Btu)

(Btu)

(%)

(g)

(g/MJ) (lb/mmbtu) (lb/mmbtu) (g/hr)

<35% of max

I

26,250 23,905

5.95

38.55

259,491

142,235

54.8%

10.16

0.07

0.16

0.09 1.71

35-53% of max 53-76% of max

II

33,000 26,730

4.88

38.37

259,928

130,532

50.2%

8.58

0.06

0.14

0.07 1.76

III

48,750 57,561

1.98

32.63

219,126

114,162

52.1%

19.58

0.16

0.38

0.20 9.87

Max capacity 75,000 74,178

IV

1.40

37.70

253,099

103,567

40.9%

36.73

0.34

0.79

0.32 25.97

Efficiency Efficiency

#DIV/0!

#DIV/0!

Average BTU/hr for 8 hr burn time

#DIV/0!

Y1 Y2 X1 X2 Z1 Z2 Z3 Z4

Test duration above 8 hours Test duration just below 8 hours Actual load (BTU/hr) for duration Y1 Actual load (BTU/hr) for duration Y2 Efficiency for duration Y1 HHV Efficiency for duration Y2 HHV Efficiency for duration Y1 LHV Efficiency for duration Y2 LHV

HHV

LHV

If the test is ASTM put a 0, if EPA put a 1

0

Maximum output rating BTU/hr:

75,000

Weighted Avg FC1500

Made with FlippingBook - professional solution for displaying marketing and sales documents online