FC1500/SF2600: EPA 2016 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL: DATE: LOCATION: CALIBRATION DUE: CALIBRATION DUE: CALIBRATION DUE:

Ken Slater

PROJECT #: G102527563

Brian Ziegler

FC1500 6/6/2016

PRODUCT:

SAMPLE ID #:

STANDARD(S): CSA B415.1

MID

EQUIPMENT

See Appenix C in final report

ASSET # - DESCRIPTION:

ASSET # - DESCRIPTION: See Appenix C in final report ASSET # - DESCRIPTION: See Appenix C in final report

CONDITIONING SAMPLE CONDITIONING (IF APPLICABLE): NA

AMBIENT TEMPERATURE: NA

Run:

1

Test Duration: Output Category:

119

3

Test Results in Accordance with CSA B415.1-09

HHV Basis

LHV Basis

Overall Efficiency

61.0% 92.4%

65.7% 92.4% 71.2%

Combustion Efficiency Heat Transfer Efficiency

66%

Output Rate (kJ/h) Burn Rate (kg/h)

(Btu/h) (lb/h) (Btu/h)

70,741

67,106 12.84 109,936

5.83

Input (kJ/h)

115,892

Test Load Weight (dry kg)

dry lb

11.56 20.99 26.57 19.58 1,222

25.47

MC wet (%) MC dry (%)

Particulate (g )

CO (g)

Test Duration (h)

1.98

Emissions Particulate

CO

g/MJ Output g/kg Dry Fuel

0.14 1.69 9.87 0.32

8.71

105.72 616.08 20.24

g/h

lb/MM Btu Output

Air/Fuel Ratio (A/F)

9.87

Made with FlippingBook - professional solution for displaying marketing and sales documents online