FC1500/SF2600: EPA 2016 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL: DATE: LOCATION: CALIBRATION DUE: CALIBRATION DUE: CALIBRATION DUE:

Ken Slater

PROJECT #: G102527563

Brian Ziegler

FC1500 6/7/2016

PRODUCT:

SAMPLE ID #:

STANDARD(S): CSA B415.1

MID

EQUIPMENT

See Appenix C in final report

ASSET # - DESCRIPTION:

ASSET # - DESCRIPTION: See Appenix C in final report ASSET # - DESCRIPTION: See Appenix C in final report

CONDITIONING SAMPLE CONDITIONING (IF APPLICABLE): NA

AMBIENT TEMPERATURE: NA

Run:

2

Test Duration: Output Category:

357

1

Test Results in Accordance with CSA B415.1-09

HHV Basis

LHV Basis

Overall Efficiency

67.2% 95.3%

72.4% 95.3% 76.0%

Combustion Efficiency Heat Transfer Efficiency

71%

Output Rate (kJ/h) Burn Rate (kg/h)

(Btu/h) (lb/h) (Btu/h)

30,867

29,281

2.31

5.09

Input (kJ/h)

45,916

43,556

Test Load Weight (dry kg)

dry lb

13.74 20.81 26.28 10.76

30.28

MC wet (%) MC dry (%)

Particulate (g )

CO (g)

951 5.95

Test Duration (h)

Emissions Particulate

CO

g/MJ Output g/kg Dry Fuel

0.06 0.78 1.81 0.14

5.18

69.26 159.92 12.04

g/h

lb/MM Btu Output

Air/Fuel Ratio (A/F)

16.92

Made with FlippingBook - professional solution for displaying marketing and sales documents online