FC1500/SF2600: EPA 2016 Certification Report

CLIENT: HY-C

PERFORMED BY: REVIEWED BY: MODEL: DATE: LOCATION: CALIBRATION DUE: CALIBRATION DUE: CALIBRATION DUE:

Ken Slater

PROJECT #: G102527563

Brian Ziegler

FC1500 6/8/2016

PRODUCT:

SAMPLE ID #:

STANDARD(S): CSA B415.1

MID

EQUIPMENT

See Appenix C in final report

ASSET # - DESCRIPTION:

ASSET # - DESCRIPTION: See Appenix C in final report ASSET # - DESCRIPTION: See Appenix C in final report

CONDITIONING SAMPLE CONDITIONING (IF APPLICABLE): NA

AMBIENT TEMPERATURE: NA

Run:

3

Test Duration: Output Category:

87

4

Test Results in Accordance with CSA B415.1-09

HHV Basis

LHV Basis

Overall Efficiency

56.7% 86.7%

61.1% 86.7% 70.5%

Combustion Efficiency Heat Transfer Efficiency

65%

Output Rate (kJ/h) Burn Rate (kg/h)

(Btu/h) (lb/h) (Btu/h)

102,052

96,807 19.93 170,602

9.04

Input (kJ/h)

179,845

Test Load Weight (dry kg)

dry lb

13.11 20.89 26.41 48.46 2,377

28.90

MC wet (%) MC dry (%)

Particulate (g )

CO (g)

Test Duration (h)

1.45

Emissions Particulate

CO

g/MJ Output g/kg Dry Fuel

0.33 3.70

16.06 181.28 1639.39

g/h

33.42

lb/MM Btu Output

0.76

37.33

Air/Fuel Ratio (A/F)

7.56