HY-C Company, LLC
Date: November 10, 2016
Project No. G102527563
Page 6 of 15
II.B INFORMATION LOG II.B(1) TEST STANDARD
From June 6, 2016 through June 9, 2016, the unit was tested for EPA emissions. For Wood Forced-Air Furnaces, the test was conducted in accordance with CSA B415.1- 2010. The fuel used for the test run was Oak cordwood. The applicable EPA regulatory limits are: Step 1 – 2016 – 0.93 lbs/MMBtu Output (0.4 g/MJ) – For furnaces rated less than 65,000 Btu/hr Step 1 – 2017 – 0.93 0.93 lbs/MMBtu Output (0.4 g/MJ) – For furnaces rated more than 65,000 Btu/hr Step 2 – 2020 – 0.15 lbs/MMBtu Output (0.026 g/MJ) II.B(2) DEVIATION FROM STANDARD METHOD No deviations from the standards were performed, however, only the applicable sections from each standard were used during all testing. II.C SUMMARY OF TEST RESULTS
The appliance tests resulted in the following performance:
Particulate Emissions: 0.368 lbs/MMBtu Output (0.159 g/MJ) Carbon Monoxide Emissions: 279.23 g/hr Heating Efficiency: 49.5% (Higher Heating Value Basis)
II.D DESCRIPTION OF TEST RUNS
RUN #1 June 6, 2016. The furnace was set to draw a category 3 draw rate. The combustion blower was turned on and off to maintain the desired heat rate. The Test Load weighed 32.63 lbs. and utilized an 8.1 lb. coal bed. The average Btu/hr output was 57,561. Burn time was 1.98 hours. The kg/hr burn rate was 5.90.