9.
Problem: Down draft on chimney caused by one or more of the following.
Remedies: • This problem may occur in factory built flues because the insulation has settled or a seam has ruptured. In masonry flues, mortar loss may be causing seepage of cooler outside air into the stack. Check entire flue for structural integrity and leakage. Correct or repair as needed, or replace or re-line the chimney. • Remove obstruction.
Possible Causes:
• Flue has a cold spot which
inhibits exhaust discharge from rising properly.
• There is an obstruction outside chimney, such as a tree. • Flue is located too close to the peak of the roof or does not rise above it to provide the proper draft.
• Increase chimney height.
10.
Problem: Odor detected in home during initial firing.
Possible Causes:
Remedies:
• The odor should disappear after a few hours of usage.
• There is an oily film that remains on the steel after the manu- facturing process. Firing the furance has raised the tempera- ture of the fire box to a level that is sufficient to vaporize the residue.
11.
Problem: Excessive smoke discharge from fuel door during reloading.
Remedies: • See #6.
Possible Causes:
• Excessively long stove pipe run from furnace flue. • Too many elbows.
• See #6.
• Insufficient draft.
• See #6.
• Excessive smoke accumulation.
• See #9.
2 1
Made with FlippingBook - professional solution for displaying marketing and sales documents online