Work Smart With Magnets Catalogue



Energise to Release

Power required to turn magnet OFF. Power removed to turn magnet ON.

• Electropermanent magnets • Sturdy bright nickel plated cylinder, passivated with body mounting • High-quality permeable iron for low remanence • Armature plates to suit

Operating Voltage Connector Options

24VDC & 240VAC (with rectified plug connector)

Hirschman connector

Mounting

Central machined hole in rear face of magnet Bright nickel plated with machined face

Finish

IP Rating

54 S2

Duty Cycle

Standard Operating Voltage

Air Gap mm

0

0.09

0.18

0.27

0.36

0.59

1.00

1.50

240VAC Product Number

24VDC Product Number

Current mA

Current mA

Pull Force (+/- 10%) kg

35 M52177/240VA 50 M52177/24VDC 240 23.00 9.10 5.00 3.10 2.30 1.70 – – 50 M52178/240VA 40 M52178/24VDC 350 55.00 31.70 20.80 15.10 11.60 7.30 4.70 2.80

Diameter mm

Dimensions mm

Weight g

Product Number

D L

B

W Connector

D1

M52177/24VDC M52178/24VDC M52177/240VA

35 48 50 78 Hirschman Style M5 x 8 50 63 50 94 Hirschman Style M5 x 8

352 874 354 880

35 48 50 81

Hirschman Hirschman

M5 x 8 M5 x 8

M52178/240VA 50 63 50 97

Armature Plates

• To fit both types • Rubber washers supplied to allow for a small degree of flex in their movement (at the back) to maximise direct contact (by allowing minimum air gap) to the electromagnet clamping face to allow maximum possible pull forces to be achieved.

To Suit Diameter mm

Product Number

Diameter mm

Height mm

Weight g

Screw

M52171/25ARM M52171/30ARM M52171/40ARM M52171/50ARM M52171/65ARM M52171/80ARM

25 30 40 50 65 80

3 4 5 6 8

M3 M4 M4 M4 M5 M6

20 / 25

15 30 50

30

35 / 40

50 65 80

100 210 400

10 12

M52171/100ARM 740 To achieve the optimum pull force, 100% contact area must be achieved using the recommended armature plate. The force will be affected if other material specifications, thickness and surfaces are used, or if the armature fails to make positive contact over the full diameter of the face of the magnet. Where misalignment is likely to be an issue we recommend that an oversized armature plate is used to ensure 100% full contact, this however will reduce the stated pull force by approximately 10% 100 M10 100

Eclipse Magnetics Work Smart with Magnets

37