Starrett Spring Testing Solutions

MMS and FMS S eries P recision D igital F orce T esters

S pecifications

MMS & FMS Series - Digital Force Testers

Material Testers Force Measurement Testers MMS-500 MMS-1000 MMS-2500 MMS-5000 FMS-500 FMS-1000 FMS- 2500

Models

FMS- 5000 5000 500 1124

N kgf lbf

500 50 112

1000 100 225

2500 250 652

5000 500 1124

500 50 112

1000 100 225

2500 250 652

Load Capacity

mm/min in/min mm/min in/min

0.001 0.00004

0.02 0.001

Crosshead Speed - MINIMUM

1525 60 0.125 4.9

Crosshead Speed - MAXIMUM

0.250 9.8

µm µin

Position Control Resolution

2.7 15,400

4.3 24,500

4.3 24,500

8.5 48,500

2.7 15,400

4.3 24,500

4.3 24,500

8.5 48,500

kN/mm lbf/in

Frame Axial Stiffness

mm in mm in mm in mm in mm in mm in

559 22 381 15 100 4 813 32 381 15

953 37.5 762 30

1257 49.5 1016 40

1257 49.5 1016 40

559 22 381 15

953 37.5 762 30

1257 49.5 1016 40

1257 49.5 1016 40

Vertical Test Space 1

Total Crosshead Travel

Throat

1270 50

1575 62

1575 62

813 32

1270 50

1575 62

1575 62

Total Height

Total Width

514 20.25

Total Depth

61 135

77 170

88 195

88 195

61 135

77 170

88 195

88 195

kg lb

Test Frame Weight

±0.5% of reading down to 1/1000 of load cell capacity. Starrett load cell sensors are supplied with a Certificate of Calibration traceable to NIST. Starrett recommends verification of load cell accuracy during installation per ASTM E4, ISO 7500-1 or EN 10002.

Load Measurement Accuracy

FMS frames cannot use extensometers

±0.010mm or 0.1% displacement (whichever is greater)

Position Measurement Accuracy

±0.005mm or 0.1% displacement (whichever is greater)

±0.5% of reading down to 1/50 of full scale with ASTM E83 class B or ISO 9513 class 0.5 extensometer

Strain Measurement Accuracy

FMS frames cannot use extensometers

Crosshead Velocity Accuracy

±0.1% of set speed at zero or constant load hold

Data Sampling

0.001 to 2000Hz

12 total channels Channel 1 & 2 for Power (5-24V) Channels 3 thru 10 for either digital inputs or outputs Channels 11 & 12 for Ground

Digital I/O

Analog Inputs Analog Outputs

1 channel @ ±10V 2 channels @ 0-10V

Extensometer Ports

2 channels for independent connection to an extensometer(s)

FMS frames cannot use extensometers

USB Interface

1 USB 2.0 connector

Single Phase Voltage (Vac) ±10% 110, 120, 220, 230, 240

Electrical Phase

Frequency

50/60Hz

°C °F °C °F

+10 to +38 °C +50 to +100 °F -40 to +66 °C -40 to +150 °F

Operating Temperature

Storage Temperature

Humidity

10% to 90%, non-condensing

CE Compliance

MMS and FMS Series Systems meet all relevant CE standards

NOTES Total vertical space is the distance from the top surface of the base plate to the bottom surface of the crosshead. MMS and FMS Test Frames use MLC and FLC Series load cell sensors only. MMS and FMS Test Frames may be used with L3, L2Plus and S2 software applications only. Starrett MMD and FMD Test frames (not shown) are available in 10kN, 30kN and 50kN capacities.

13

starrett .com

Made with FlippingBook - professional solution for displaying marketing and sales documents online