MMS and FMS S eries P recision D igital F orce T esters
S pecifications
MMS & FMS Series - Digital Force Testers
Material Testers Force Measurement Testers MMS-500 MMS-1000 MMS-2500 MMS-5000 FMS-500 FMS-1000 FMS- 2500
Models
FMS- 5000 5000 500 1124
N kgf lbf
500 50 112
1000 100 225
2500 250 652
5000 500 1124
500 50 112
1000 100 225
2500 250 652
Load Capacity
mm/min in/min mm/min in/min
0.001 0.00004
0.02 0.001
Crosshead Speed - MINIMUM
1525 60 0.125 4.9
Crosshead Speed - MAXIMUM
0.250 9.8
µm µin
Position Control Resolution
2.7 15,400
4.3 24,500
4.3 24,500
8.5 48,500
2.7 15,400
4.3 24,500
4.3 24,500
8.5 48,500
kN/mm lbf/in
Frame Axial Stiffness
mm in mm in mm in mm in mm in mm in
559 22 381 15 100 4 813 32 381 15
953 37.5 762 30
1257 49.5 1016 40
1257 49.5 1016 40
559 22 381 15
953 37.5 762 30
1257 49.5 1016 40
1257 49.5 1016 40
Vertical Test Space 1
Total Crosshead Travel
Throat
1270 50
1575 62
1575 62
813 32
1270 50
1575 62
1575 62
Total Height
Total Width
514 20.25
Total Depth
61 135
77 170
88 195
88 195
61 135
77 170
88 195
88 195
kg lb
Test Frame Weight
±0.5% of reading down to 1/1000 of load cell capacity. Starrett load cell sensors are supplied with a Certificate of Calibration traceable to NIST. Starrett recommends verification of load cell accuracy during installation per ASTM E4, ISO 7500-1 or EN 10002.
Load Measurement Accuracy
FMS frames cannot use extensometers
±0.010mm or 0.1% displacement (whichever is greater)
Position Measurement Accuracy
±0.005mm or 0.1% displacement (whichever is greater)
±0.5% of reading down to 1/50 of full scale with ASTM E83 class B or ISO 9513 class 0.5 extensometer
Strain Measurement Accuracy
FMS frames cannot use extensometers
Crosshead Velocity Accuracy
±0.1% of set speed at zero or constant load hold
Data Sampling
0.001 to 2000Hz
12 total channels Channel 1 & 2 for Power (5-24V) Channels 3 thru 10 for either digital inputs or outputs Channels 11 & 12 for Ground
Digital I/O
Analog Inputs Analog Outputs
1 channel @ ±10V 2 channels @ 0-10V
Extensometer Ports
2 channels for independent connection to an extensometer(s)
FMS frames cannot use extensometers
USB Interface
1 USB 2.0 connector
Single Phase Voltage (Vac) ±10% 110, 120, 220, 230, 240
Electrical Phase
Frequency
50/60Hz
°C °F °C °F
+10 to +38 °C +50 to +100 °F -40 to +66 °C -40 to +150 °F
Operating Temperature
Storage Temperature
Humidity
10% to 90%, non-condensing
CE Compliance
MMS and FMS Series Systems meet all relevant CE standards
NOTES Total vertical space is the distance from the top surface of the base plate to the bottom surface of the crosshead. MMS and FMS Test Frames use MLC and FLC Series load cell sensors only. MMS and FMS Test Frames may be used with L3, L2Plus and S2 software applications only. Starrett MMD and FMD Test frames (not shown) are available in 10kN, 30kN and 50kN capacities.
13
starrett .com